prtalertdescription
HP-Color-LaserJet-4500-MIB ·
.1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.8
Object
scalar
optional
OctetString
A description of this alert entry in the localization
specified by prtGeneralCurrentLocalization. The description is
provided by the printer to further elaborate on the enumerated
alert or provide information in the case where the code is
classified as `other' or `unknown'. The printer is required
to return a description string but the string may be a null
string.
Additional information:
The alert table in LaserJet 4500 will hold up to 32 entries. If the table is full and a new
alert occurs, the table will be managed as specified in the section 'Alert Table Management' of the Printer MIB
(RFC1759).
Context
- MIB
- HP-Color-LaserJet-4500-MIB
- OID
.1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.8- Type
- scalar
- Access
- readonly
- Status
- optional
- Parent
- prtAlertEntry
- Siblings
- 7
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| prtalertseveritylevel optional The level of severity of this alert table entry. The printer
determines the severity level assigned to each entry into the
table.
Additional information:
The ale… | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.2 |
| prtalerttraininglevel optional See textual convention PrtAlertTrainingLevelTC
Additional information:
The value of this object depends on the alert condition. e.g.,
ePuntrained: Paper out.
ePtrained: Toner… | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.3 |
| prtalertgroup optional The type of sub-unit within the printer model that this alert
is related. Input, output, and markers are examples of
printer model groups, i.e., examples of types of sub-units.
W… | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.4 |
| prtalertgroupindex optional An index of the row within the principle table in the
group identified by prtAlertGroup that represents the
sub-unit of the printer that caused this alert. The
combination of the… | scalar | Integer32 | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.5 |
| prtalertlocation optional The sub-unit location that is defined by the printer
manufacturer to further refine the location of this alert
within the designated sub-unit. The location is used in
conjunction… | scalar | Integer32 | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.6 |
| prtalertcode optional See associated textual convention PrtAlertCodeTC
Additional information:
The alert table in LaserJet 4500 will hold up to 32 entries. If the table is full and a new
alert occurs… | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.7 |
| prtalerttime optional The value of sysUpTime at the time that this alert was
generated.
Additional information:
The alert table in LaserJet 4500 will hold up to 32 entries. If the tabl… | scalar | Integer32 | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.9 |