prtalertcode
HP-Color-LaserJet-4500-MIB ·
.1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.7
Object
scalar
optional
Enumeration
See associated textual convention PrtAlertCodeTC Additional information: The alert table in LaserJet 4500 will hold up to 32 entries. If the table is full and a new alert occurs, the table will be managed as specified in the section 'Alert Table Management' of the Printer MIB (RFC1759).
Context
- MIB
- HP-Color-LaserJet-4500-MIB
- OID
.1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.7- Type
- scalar
- Access
- readonly
- Status
- optional
- Parent
- prtAlertEntry
- Siblings
- 7
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | ePother |
3 | ePcoverOpened |
8 | ePjam |
9 | ePsubunitMissing |
10 | ePsubunitLifeAlmostOver |
11 | ePsubunitLifeOver |
12 | ePsubunitAlmostEmpty |
13 | ePsubunitEmpty |
15 | ePsubunitFull |
18 | ePsubunitOpened |
22 | ePsubunitOffline |
23 | ePsubunitPowerSaver |
29 | ePsubunitRecoverableFailure |
30 | ePsubunitUnrecoverableFailure |
33 | ePsubunitMotorFailure |
809 | ePInputMediaChangeRequest |
1001 | ePmarkerFuserUnderTemperature |
1002 | ePmarkerFuserOverTemperature |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| prtalertseveritylevel optional The level of severity of this alert table entry. The printer
determines the severity level assigned to each entry into the
table.
Additional information:
The ale… | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.2 |
| prtalerttraininglevel optional See textual convention PrtAlertTrainingLevelTC
Additional information:
The value of this object depends on the alert condition. e.g.,
ePuntrained: Paper out.
ePtrained: Toner… | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.3 |
| prtalertgroup optional The type of sub-unit within the printer model that this alert
is related. Input, output, and markers are examples of
printer model groups, i.e., examples of types of sub-units.
W… | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.4 |
| prtalertgroupindex optional An index of the row within the principle table in the
group identified by prtAlertGroup that represents the
sub-unit of the printer that caused this alert. The
combination of the… | scalar | Integer32 | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.5 |
| prtalertlocation optional The sub-unit location that is defined by the printer
manufacturer to further refine the location of this alert
within the designated sub-unit. The location is used in
conjunction… | scalar | Integer32 | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.6 |
| prtalertdescription optional A description of this alert entry in the localization
specified by prtGeneralCurrentLocalization. The description is
provided by the printer to further elaborate on the enumerate… | scalar | OctetString | .1.3.6.1.4.1.11.2.3.9.4.2.2.18.1.1.8 |
| prtalerttime optional The value of sysUpTime at the time that this alert was
generated.
Additional information: