on-off-line
HP-Color-LaserJet-4500-MIB ·
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.5
Object
scalar
optional
r/w
Enumeration
To bring the PDL processing sub-system on or off line.
If the device is a printer, then the printer does not
process print job data when the printer is off line.
PML communication persists.
Additional information:
When the printer is in the Offline state,
printing will stop as soon as possible (no more sheets
of media are pulled from input trays). The I/O
is taken offline.
Setting to eOnline has the following effect:
Printer will immediately go to or remain in the Online
state; <noError> status is returned.
If the printer's current state
is Offline with a pending error condition that
prevents the printer from going to the Online
state, the printer will remain in the Offline state;
<genErr> status is returned
Setting to eOffline has the following effect:
Printer will immediately go to or remain in the
Offline state; <noError> status is returned.
If pages are being printed, those pages will complete
with the printer in the Offline state.
Setting to eOfflineAtEndOfJob has the following
affect:
If not in a job or already in the Offline state, the
printer will immediately go to or remain in the
Offline state; <noError> status is returned.
If in a job and the current state is Online, the
printer will remain in the Online state, with the
value of this object as eOfflineAtEndOfJob, until the
end of the job; <noError> status is returned. At the end of
the job, the printer goes to the Offline state and the
value of this object becomes eOffline.
Setting this object to eOffline or eOnline before the
end of the job causes the action for that value to be
taken immediately.
Context
- MIB
- HP-Color-LaserJet-4500-MIB
- OID
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.5- Type
- scalar
- Access
- readwrite
- Status
- optional
- Parent
- status-system
- Siblings
- 9
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | eOnline |
2 | eOffline |
3 | eOfflineAtEndOfJob |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| job-input-auto-continue-timeout optional The number of seconds the device waits after a job
related continuable error occurs before automatically
continuing. An example job related continuable error is
the job requestin… | scalar | Integer32 | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.35 |
| job-input-auto-continue-mode optional Returns or sets the device behavior when the desired
media is not currently available.
cCancelJob - The device cancels the job. The device
POS should explain what happens if th… | scalar | OctetString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.36 |
| background-message | node | - | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37 |
| error-log-clear optional Setting this object clears all the entries in the error
log sub-tree. | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.38 |
| job-output-auto-continue-timeout optional Returns or sets the time that the printer will wait
after an output bin becomes full and the printer is
trying to deliver a sheet of media to that output bin.
When the timeout exp… | scalar | Integer32 | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.40 |
| localization-languages-supported optional The list of languages supported by the device. The
languages are primarily, but not limited to, two
character codes from ISO 639, each separated by a comma
character.
Additional i… | scalar | DisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.52 |
| localization-countries-supported optional The list of countries supported by the device. The
countries are primarily, but not limited to, two
character codes from ISO 3166, each separated by a comma
character.
Additional … | scalar | DisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.53 |
| continue optional A device can support a class of errors called
continuable errors. When a continuable error is
encountered, the device requires a continue event to
occur before the device will co… | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.6 |
| auto-continue optional Indicates if the device will automatically continue
after encountering a continuable error. If AUTO-
CONTINUE is set to eOn, the device will automatically
generate continue event… | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.7 |