hpSwitchRadiusTrackPassEncrypt

HP-AUTH-MIB · .1.3.6.1.4.1.11.2.14.11.5.1.16.6.20

Object

scalar r/w OctetString
The password is configured in the encrypted form.
The password after decryption is sent in Access-Request
packet to the RADIUS server for tracking.
This object can be read or written only when
hpSwitchAuthenticationEncryptCredentialsMethod is set to a
value other than none(0). At most one of the
hpSwitchRadiusTrackingPassword and
hpSwitchRadiusTrackPassEncrypt can be set in any
transaction. This object should only be written with an
encrypted password string previously read from a
compatible Networking device.

Context

MIB
HP-AUTH-MIB
OID
.1.3.6.1.4.1.11.2.14.11.5.1.16.6.20
Type
scalar
Access
readwrite
Status
current
Parent
hpSwitchRadiusConfig
Siblings
24

Syntax

OctetString

Values & Constraints

Object Constraints
range: 0-256

Related Objects

Sibling Objects