upsTrapAlarmShutdownPendinggen
GESINGLEUPS-MIB ·
.1.3.6.1.4.1.818.1.1.10.11.22
Object
notification
A upsShutdownAfterDelay countdown is underway.
Context
- MIB
- GESINGLEUPS-MIB
- OID
.1.3.6.1.4.1.818.1.1.10.11.22- Type
- notification
- Status
- current
- Parent
- geUPSTrapsgen
- Siblings
- 65
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsTrapAlarmBatteryBadgen One or more batteries have been determined to require
replacement. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.1 |
| upsTrapAlarmBypassBadgen The Bypass is out of tolerance. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.10 |
| upsTrapAlarmOutputOffAsRequestedgen The UPS has shutdown as requested, i.e., the output
is off. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.11 |
| upsTrapAlarmUpsOffAsRequestedgen The entire UPS has shutdown as commanded. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.12 |
| upsTrapAlarmValueLowgen A measurement value reached a value below its low-level threshold. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.129 |
| upsTrapAlarmChargerFailedgen An uncorrected problem has been detected within the
UPS charger subsystem. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.13 |
| upsTrapAlarmValueHighgen A measurement value reached a value higher than its high-level threshold. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.130 |
| upsTrapAlarmValueLowRestoredgen A ValueLow alarm condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.133 |
| upsTrapAlarmValueHighRestoredgen A ValueHigh alarm condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.134 |
| upsTrapAlarmUpsOutputOffgen The output of the UPS is in the off state. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.14 |
| upsTrapAlarmUpsSystemOffgen The UPS system is in the off state. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.15 |
| upsTrapAlarmFanFailuregen The failure of one or more fans in the UPS has been
detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.16 |
| upsTrapAlarmFuseFailuregen The failure of one or more fuses has been detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.17 |
| upsTrapAlarmGeneralFaultgen A general fault in the UPS has been detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.18 |
| upsTrapAlarmDiagnosticTestFailedgen The result of the last diagnostic test indicates a
failure. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.19 |
| upsTrapAlarmOnBatterygen The UPS is drawing power from the batteries. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.2 |
| upsTrapAlarmCommunicationsLostgen A problem has been encountered in the communication
between the agent and the UPS. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.20 |
| upsTrapAlarmAwaitingPowergen The UPS output is off and the UPS is awaiting the
return of the input power (*). | notification | - | .1.3.6.1.4.1.818.1.1.10.11.21 |
| upsTrapAlarmShutdownImminentgen The UPS will turn off power to the load in less than
5 seconds; this may be either a timed shutdown or a
low battery shutdown. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.23 |
| upsTrapAlarmTestInProgressgen A test is in progress, as initiated and indicated by
the Test Group. Tests initiated via other
implementation-specific mechanisms can indicate the
presence of the testing in the … | notification | - | .1.3.6.1.4.1.818.1.1.10.11.24 |
| upsTrapAlarmReceptacleOffgen A receptacle has been switched off. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.25 |
| upsTrapAlarmHighspeedBusFailuregen A problem on the Highspeed Bus communication is detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.26 |
| upsTrapAlarmHighspeedBusJACRCFailuregen A CRC failure on the Highspeed Bus JA is detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.27 |
| upsTrapAlarmConnectivityBusFailuregen A Connectivity Bus failure is detected | notification | - | .1.3.6.1.4.1.818.1.1.10.11.28 |
| upsTrapAlarmHighspeedBusJBCRCFailuregen A CRC failure on the Highspeed Bus JB is detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.29 |
| upsTrapAlarmLowBatterygen The remaining battery run-time is less than or equal
to upsConfigLowBattTime. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.3 |
| upsTrapAlarmCurrentSharingFailuregen An high current sharing on the parallel system is detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.30 |
| upsTrapAlarmDCRippleFailuregen An high ripple voltage on his DC link is detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.31 |
| upsTrapAlarmBatteryBadRestoredgen A Battery bad condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.33 |
| upsTrapAlarmOnBatteryRestoredgen The UPS is drawing power from mains again. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.34 |
| upsTrapAlarmLowBatteryRestoredgen A Low Battery condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.35 |
| upsTrapAlarmDepletedBatteryRestoredgen A Depleted Battery condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.36 |
| upsTrapAlarmTempBadRestoredgen A bad temperature condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.37 |
| upsTrapAlarmInputBadRestoredgen An input bad condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.38 |
| upsTrapAlarmOutputBadRestoredgen An output bad condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.39 |
| upsTrapAlarmDepletedBatterygen The UPS will be unable to sustain the present load
when and if the utility power is lost) | notification | - | .1.3.6.1.4.1.818.1.1.10.11.4 |
| upsTrapAlarmOutputOverloadRestoredgen An output overload condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.40 |
| upsTrapAlarmOnBypassRestoredgen An On Bypass condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.41 |
| upsTrapAlarmBypassBadRestoredgen A Bypass bad condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.42 |
| upsTrapAlarmOutputOffAsRequestedRestoredgen A request shutdown has been restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.43 |
| upsTrapAlarmUpsOffAsRequestedRestoredgen A entire UPS command has been restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.44 |
| upsTrapAlarmChargerFailedRestoredgen A Charger Failer condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.45 |
| upsTrapAlarmUpsOutputOngen The output of the UPS switched in the on state. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.46 |
| upsTrapAlarmUpsSystemOngen The UPS system is switched in the on state. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.47 |
| upsTrapAlarmFanFailureRestoredgen A Fan failure condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.48 |
| upsTrapAlarmFuseFailureRestoredgen A Fuse failure condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.49 |
| upsTrapAlarmTempBadgen A temperature is out of tolerance. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.5 |
| upsTrapAlarmGeneralFaultRestoredgen A general fault is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.50 |
| upsTrapAlarmDiagnosticTestFailedRestoredgen A last diagnostic test indicates a failure is
restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.51 |
| upsTrapAlarmCommunicationsLostRestoredgen A problem in the communication between the agent
and the UPS is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.52 |
| upsTrapAlarmAwaitingPowerRestoredgen A awaiting power condition is restored (*). | notification | - | .1.3.6.1.4.1.818.1.1.10.11.53 |
| upsTrapAlarmShutdownPendingRestoredgen A upsShutdownAfterDelay countdown is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.54 |
| upsTrapAlarmShutdownImminentRestoredgen A shutdown imminent condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.55 |
| upsTrapAlarmTestInProgressRestoredgen The test is in progress is terminated. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.56 |
| upsTrapAlarmReceptacleOn A receptacle has been switched on. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.57 |
| upsTrapAlarmHighspeedBusRestoredgen A problem on the Highspeed Bus communication is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.58 |
| upsTrapAlarmHighspeedBusJACRCRestoredAgen A CRC failure on the Highspeed Bus JA is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.59 |
| upsTrapAlarmInputBadgen An input condition is out of tolerance. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.6 |
| upsTrapAlarmConnectivityBusRestoredgen A problem on the Connectivity Bus communication is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.60 |
| upsTrapAlarmHighspeedBusJBCRCRestoredBgen A CRC failure on the Highspeed Bus JB is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.61 |
| upsTrapAlarmCurrentSharingRestoredgen An high current sharing on the parallel system is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.62 |
| upsTrapAlarmDCRippleRestoredgen An high ripple voltage on his DC link is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.63 |
| upsTrapAlarmOutputBadgen An output condition (other than OutputOverload) is
out of tolerance. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.7 |
| upsTrapAlarmOutputOverloadgen The output load exceeds the UPS output capacity. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.8 |
| upsTrapAlarmOnBypassgen The Bypass is presently engaged on the UPS. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsShutdownAfterDelaygen Setting this object will shutdown (i.e., turn off)
either the UPS output or the UPS system (as determined
by the value of upsShutdownType at the time of
shutdown) after the indica… | scalar | seconds Integer32 | .1.3.6.1.4.1.818.1.1.10.8.2 |