upsTrapAlarmOnBypassgen
GESINGLEUPS-MIB ·
.1.3.6.1.4.1.818.1.1.10.11.9
Object
notification
The Bypass is presently engaged on the UPS.
Context
- MIB
- GESINGLEUPS-MIB
- OID
.1.3.6.1.4.1.818.1.1.10.11.9- Type
- notification
- Status
- current
- Parent
- geUPSTrapsgen
- Siblings
- 65
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsTrapAlarmBatteryBadgen One or more batteries have been determined to require
replacement. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.1 |
| upsTrapAlarmBypassBadgen The Bypass is out of tolerance. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.10 |
| upsTrapAlarmOutputOffAsRequestedgen The UPS has shutdown as requested, i.e., the output
is off. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.11 |
| upsTrapAlarmUpsOffAsRequestedgen The entire UPS has shutdown as commanded. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.12 |
| upsTrapAlarmValueLowgen A measurement value reached a value below its low-level threshold. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.129 |
| upsTrapAlarmChargerFailedgen An uncorrected problem has been detected within the
UPS charger subsystem. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.13 |
| upsTrapAlarmValueHighgen A measurement value reached a value higher than its high-level threshold. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.130 |
| upsTrapAlarmValueLowRestoredgen A ValueLow alarm condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.133 |
| upsTrapAlarmValueHighRestoredgen A ValueHigh alarm condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.134 |
| upsTrapAlarmUpsOutputOffgen The output of the UPS is in the off state. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.14 |
| upsTrapAlarmUpsSystemOffgen The UPS system is in the off state. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.15 |
| upsTrapAlarmFanFailuregen The failure of one or more fans in the UPS has been
detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.16 |
| upsTrapAlarmFuseFailuregen The failure of one or more fuses has been detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.17 |
| upsTrapAlarmGeneralFaultgen A general fault in the UPS has been detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.18 |
| upsTrapAlarmDiagnosticTestFailedgen The result of the last diagnostic test indicates a
failure. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.19 |
| upsTrapAlarmOnBatterygen The UPS is drawing power from the batteries. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.2 |
| upsTrapAlarmCommunicationsLostgen A problem has been encountered in the communication
between the agent and the UPS. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.20 |
| upsTrapAlarmAwaitingPowergen The UPS output is off and the UPS is awaiting the
return of the input power (*). | notification | - | .1.3.6.1.4.1.818.1.1.10.11.21 |
| upsTrapAlarmShutdownPendinggen A upsShutdownAfterDelay countdown is underway. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.22 |
| upsTrapAlarmShutdownImminentgen The UPS will turn off power to the load in less than
5 seconds; this may be either a timed shutdown or a
low battery shutdown. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.23 |
| upsTrapAlarmTestInProgressgen A test is in progress, as initiated and indicated by
the Test Group. Tests initiated via other
implementation-specific mechanisms can indicate the
presence of the testing in the … | notification | - | .1.3.6.1.4.1.818.1.1.10.11.24 |
| upsTrapAlarmReceptacleOffgen A receptacle has been switched off. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.25 |
| upsTrapAlarmHighspeedBusFailuregen A problem on the Highspeed Bus communication is detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.26 |
| upsTrapAlarmHighspeedBusJACRCFailuregen A CRC failure on the Highspeed Bus JA is detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.27 |
| upsTrapAlarmConnectivityBusFailuregen A Connectivity Bus failure is detected | notification | - | .1.3.6.1.4.1.818.1.1.10.11.28 |
| upsTrapAlarmHighspeedBusJBCRCFailuregen A CRC failure on the Highspeed Bus JB is detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.29 |
| upsTrapAlarmLowBatterygen The remaining battery run-time is less than or equal
to upsConfigLowBattTime. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.3 |
| upsTrapAlarmCurrentSharingFailuregen An high current sharing on the parallel system is detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.30 |
| upsTrapAlarmDCRippleFailuregen An high ripple voltage on his DC link is detected. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.31 |
| upsTrapAlarmBatteryBadRestoredgen A Battery bad condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.33 |
| upsTrapAlarmOnBatteryRestoredgen The UPS is drawing power from mains again. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.34 |
| upsTrapAlarmLowBatteryRestoredgen A Low Battery condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.35 |
| upsTrapAlarmDepletedBatteryRestoredgen A Depleted Battery condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.36 |
| upsTrapAlarmTempBadRestoredgen A bad temperature condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.37 |
| upsTrapAlarmInputBadRestoredgen An input bad condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.38 |
| upsTrapAlarmOutputBadRestoredgen An output bad condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.39 |
| upsTrapAlarmDepletedBatterygen The UPS will be unable to sustain the present load
when and if the utility power is lost) | notification | - | .1.3.6.1.4.1.818.1.1.10.11.4 |
| upsTrapAlarmOutputOverloadRestoredgen An output overload condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.40 |
| upsTrapAlarmOnBypassRestoredgen An On Bypass condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.41 |
| upsTrapAlarmBypassBadRestoredgen A Bypass bad condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.42 |
| upsTrapAlarmOutputOffAsRequestedRestoredgen A request shutdown has been restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.43 |
| upsTrapAlarmUpsOffAsRequestedRestoredgen A entire UPS command has been restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.44 |
| upsTrapAlarmChargerFailedRestoredgen A Charger Failer condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.45 |
| upsTrapAlarmUpsOutputOngen The output of the UPS switched in the on state. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.46 |
| upsTrapAlarmUpsSystemOngen The UPS system is switched in the on state. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.47 |
| upsTrapAlarmFanFailureRestoredgen A Fan failure condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.48 |
| upsTrapAlarmFuseFailureRestoredgen A Fuse failure condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.49 |
| upsTrapAlarmTempBadgen A temperature is out of tolerance. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.5 |
| upsTrapAlarmGeneralFaultRestoredgen A general fault is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.50 |
| upsTrapAlarmDiagnosticTestFailedRestoredgen A last diagnostic test indicates a failure is
restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.51 |
| upsTrapAlarmCommunicationsLostRestoredgen A problem in the communication between the agent
and the UPS is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.52 |
| upsTrapAlarmAwaitingPowerRestoredgen A awaiting power condition is restored (*). | notification | - | .1.3.6.1.4.1.818.1.1.10.11.53 |
| upsTrapAlarmShutdownPendingRestoredgen A upsShutdownAfterDelay countdown is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.54 |
| upsTrapAlarmShutdownImminentRestoredgen A shutdown imminent condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.55 |
| upsTrapAlarmTestInProgressRestoredgen The test is in progress is terminated. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.56 |
| upsTrapAlarmReceptacleOn A receptacle has been switched on. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.57 |
| upsTrapAlarmHighspeedBusRestoredgen A problem on the Highspeed Bus communication is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.58 |
| upsTrapAlarmHighspeedBusJACRCRestoredAgen A CRC failure on the Highspeed Bus JA is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.59 |
| upsTrapAlarmInputBadgen An input condition is out of tolerance. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.6 |
| upsTrapAlarmConnectivityBusRestoredgen A problem on the Connectivity Bus communication is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.60 |
| upsTrapAlarmHighspeedBusJBCRCRestoredBgen A CRC failure on the Highspeed Bus JB is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.61 |
| upsTrapAlarmCurrentSharingRestoredgen An high current sharing on the parallel system is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.62 |
| upsTrapAlarmDCRippleRestoredgen An high ripple voltage on his DC link is restored. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.63 |
| upsTrapAlarmOutputBadgen An output condition (other than OutputOverload) is
out of tolerance. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.7 |
| upsTrapAlarmOutputOverloadgen The output load exceeds the UPS output capacity. | notification | - | .1.3.6.1.4.1.818.1.1.10.11.8 |