upsWellKnownAlarmsfourth
GEPARALLELUPS-MIB ·
.1.3.6.1.4.1.818.1.1.14.6.3
Object
node
No description available.
Context
- MIB
- GEPARALLELUPS-MIB
- OID
.1.3.6.1.4.1.818.1.1.14.6.3- Type
- node
- Parent
- upsAlarmfourth
- Siblings
- 3
- Children
- 31
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsAlarmsPresentfourth The present number of active alarm conditions.(*) | scalar | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.818.1.1.14.6.1 |
| upsAlarmFourthTable A list of alarm table entries. The table contains
zero, one, or many rows at any moment, depending upon
the number of alarm conditions in effect. The table
is initially empty at… | table | - | .1.3.6.1.4.1.818.1.1.14.6.2 |
| upsAlarmMaskAfourth Specifies which alarm can be handled by the UPS.
The 'Mask' parameter is a Long Integer32. The meaning
of every bit is the same as for the 'upsAlarmGroupA'
command. A bit having v… | scalar | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.818.1.1.14.6.4 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsAlarmBatteryBadfourth One or more batteries have been determined to require
replacement.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.1 |
| upsAlarmBypassBadfourth The Bypass is out of tolerance.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.10 |
| upsAlarmOutputOffAsRequestedfourth The UPS has shutdown as requested, i.e., the output
is off.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.11 |
| upsAlarmUpsOffAsRequestedfourth The entire UPS has shutdown as commanded.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.12 |
| upsAlarmChargerFailedfourth An uncorrected problem has been detected within the
UPS charger subsystem.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.13 |
| upsAlarmUpsOutputOfffourth The output of the UPS is in the off state.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.14 |
| upsAlarmUpsSystemOfffourth The UPS system is in the off state.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.15 |
| upsAlarmFanFailurefourth The failure of one or more fans in the UPS has been
detected.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.16 |
| upsAlarmFuseFailurefourth The failure of one or more fuses has been detected.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.17 |
| upsAlarmGeneralFaultfourth A general fault in the UPS has been detected.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.18 |
| upsAlarmDiagnosticTestFailedfourth The result of the last diagnostic test indicates a
failure.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.19 |
| upsAlarmOnBatteryfourth The UPS is drawing power from the batteries.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.2 |
| upsAlarmCommunicationsLostfourth A problem has been encountered in the communications
between the agent and the UPS.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.20 |
| upsAlarmAwaitingPowerfourth The UPS output is off and the UPS is awaiting the
return of input power.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.21 |
| upsAlarmShutdownPendingfourth A upsShutdownAfterDelay countdown is underway.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.22 |
| upsAlarmShutdownImminentfourth The UPS will turn off power to the load in less than
5 fourths; this may be either a timed shutdown or a
low battery shutdown.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.23 |
| upsAlarmTestInProgressfourth A test is in progress, as initiated and indicated by
the Test Group. Tests initiated via other
implementation-specific mechanisms can indicate the
presence of the testing in the … | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.24 |
| upsAlarmReceptacleOfffourth The receptacle are switch off | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.25 |
| upsAlarmHighSpeedBusFailurefourth A problem on the High Speed Bus communication is detected | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.26 |
| upsAlarmHighSpeedBusJACRCFailurefourth A High Speed Bus CRC failure on Bus JA is detected. | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.27 |
| upsAlarmConnectivityBusFailurefourth A problem on the Connectivity Bus communication is detected | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.28 |
| upsAlarmHighSpeedBusJBCRCFailurefourth A High Speed Bus CRC failure on Bus JB is detected. | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.29 |
| upsAlarmLowBatteryfourth The remaining battery run-time is less than or equal
to upsConfigLowBattTime.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.3 |
| upsAlarmCurrentSharingfourth The UPS detects an high current sharing on the parallel system. | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.30 |
| upsAlarmDCRipplefourth The UPS detects an high ripple voltage on his DC link. | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.31 |
| upsAlarmDepletedBatteryfourth The UPS will be unable to sustain the present load
when and if the utility power is lost.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.4 |
| upsAlarmTempBadfourth A temperature is out of tolerance.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.5 |
| upsAlarmInputBadfourth An input condition is out of tolerance.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.6 |
| upsAlarmOutputBadfourth An output condition (other than OutputOverload) is
out of tolerance.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.7 |
| upsAlarmOutputOverloadfourth The output load exceeds the UPS output capacity.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.8 |
| upsAlarmOnBypassfourth The Bypass is presently engaged on the UPS.(*) | node | - | .1.3.6.1.4.1.818.1.1.14.6.3.9 |