upsTrapAlarmGeneralFaultRestoredeighth
GEPARALLELUPS-MIB ·
.1.3.6.1.4.1.818.1.1.18.11.50
Object
notification
A general fault is restored.
Context
- MIB
- GEPARALLELUPS-MIB
- OID
.1.3.6.1.4.1.818.1.1.18.11.50- Type
- notification
- Status
- current
- Parent
- geUPSTrapseighth
- Siblings
- 65
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsTrapAlarmBatteryBadeighth One or more batteries have been determined to require
replacement. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.1 |
| upsTrapAlarmBypassBadeighth The Bypass is out of tolerance. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.10 |
| upsTrapAlarmOutputOffAsRequestedeighth The UPS has shutdown as requested, i.e., the output
is off. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.11 |
| upsTrapAlarmUpsOffAsRequestedeighth The entire UPS has shutdown as commanded. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.12 |
| upsTrapAlarmValueLoweighth A measurement value reached a value below its low-level threshold. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.129 |
| upsTrapAlarmChargerFailedeighth An uncorrected problem has been detected within the
UPS charger subsystem. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.13 |
| upsTrapAlarmValueHigheighth A measurement value reached a value higher than its high-level threshold. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.130 |
| upsTrapAlarmValueLowRestoredeighth A ValueLow alarm condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.133 |
| upsTrapAlarmValueHighRestoredeighth A ValueHigh alarm condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.134 |
| upsTrapAlarmUpsOutputOffeighth The output of the UPS is in the off state. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.14 |
| upsTrapAlarmUpsSystemOffeighth The UPS system is in the off state. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.15 |
| upsTrapAlarmFanFailureeighth The failure of one or more fans in the UPS has been
detected. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.16 |
| upsTrapAlarmFuseFailureeighth The failure of one or more fuses has been detected. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.17 |
| upsTrapAlarmGeneralFaulteighth A general fault in the UPS has been detected. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.18 |
| upsTrapAlarmDiagnosticTestFailedeighth The result of the last diagnostic test indicates a
failure. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.19 |
| upsTrapAlarmOnBatteryeighth The UPS is drawing power from the batteries. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.2 |
| upsTrapAlarmCommunicationsLosteighth A problem has been encountered in the communication
between the agent and the UPS. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.20 |
| upsTrapAlarmAwaitingPowereighth The UPS output is off and the UPS is awaiting the
return of the input power (*). | notification | - | .1.3.6.1.4.1.818.1.1.18.11.21 |
| upsTrapAlarmShutdownPendingeighth A upsShutdownAfterDelay countdown is underway. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.22 |
| upsTrapAlarmShutdownImminenteighth The UPS will turn off power to the load in less than
5 eighths; this may be either a timed shutdown or a
low battery shutdown. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.23 |
| upsTrapAlarmTestInProgresseighth A test is in progress, as initiated and indicated by
the Test Group. Tests initiated via other
implementation-specific mechanisms can indicate the
presence of the testing in the … | notification | - | .1.3.6.1.4.1.818.1.1.18.11.24 |
| upsTrapAlarmReceptacleOffeighth A receptacle has been switched off. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.25 |
| upsTrapAlarmHighspeedBusFailureeighth A problem on the Highspeed Bus communication is detected. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.26 |
| upsTrapAlarmHighspeedBusJACRCFailureeighth A CRC failure on the Highspeed Bus JA is detected. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.27 |
| upsTrapAlarmConnectivityBusFailureeighth A problem on the Connectivity Bus communication is detected. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.28 |
| upsTrapAlarmHighspeedBusJBCRCFailureeighth A CRC failure on the Highspeed Bus JB is detected. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.29 |
| upsTrapAlarmLowBatteryeighth The remaining battery run-time is less than or equal
to upsConfigLowBattTime. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.3 |
| upsTrapAlarmCurrentSharingFailureeighth An high current sharing on the parallel system is detected. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.30 |
| upsTrapAlarmDCRippleFailureeighth An high ripple voltage on his DC link is detected. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.31 |
| upsTrapAlarmBatteryBadRestoredeighth A Battery bad condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.33 |
| upsTrapAlarmOnBatteryRestoredeighth The UPS is drawing power from mains again. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.34 |
| upsTrapAlarmLowBatteryRestoredeighth A Low Battery condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.35 |
| upsTrapAlarmDepletedBatteryRestoredeighth A Depleted Battery condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.36 |
| upsTrapAlarmTempBadRestoredeighth A bad temperature condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.37 |
| upsTrapAlarmInputBadRestoredeighth An input bad condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.38 |
| upsTrapAlarmOutputBadRestoredeighth An output bad condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.39 |
| upsTrapAlarmDepletedBatteryeighth The UPS will be unable to sustain the present load
when and if the utility power is lost) | notification | - | .1.3.6.1.4.1.818.1.1.18.11.4 |
| upsTrapAlarmOutputOverloadRestoredeighth An output overload condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.40 |
| upsTrapAlarmOnBypassRestoredeighth An On Bypass condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.41 |
| upsTrapAlarmBypassBadRestoredeighth A Bypass bad condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.42 |
| upsTrapAlarmOutputOffAsRequestedRestoredeighth A request shutdown has been restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.43 |
| upsTrapAlarmUpsOffAsRequestedRestoredeighth A entire UPS command has been restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.44 |
| upsTrapAlarmChargerFailedRestoredeighth A Charger Failer condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.45 |
| upsTrapAlarmUpsOutputOneighth The output of the UPS switched in the on state. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.46 |
| upsTrapAlarmUpsSystemOneighth The UPS system is switched in the on state. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.47 |
| upsTrapAlarmFanFailureRestoredeighth A Fan failure condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.48 |
| upsTrapAlarmFuseFailureRestoredeighth A Fuse failure condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.49 |
| upsTrapAlarmTempBadeighth A temperature is out of tolerance. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.5 |
| upsTrapAlarmDiagnosticTestFailedRestoredeighth A last diagnostic test indicates a failure is
restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.51 |
| upsTrapAlarmCommunicationsLostRestoredeighth A problem in the communication between the agent
and the UPS is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.52 |
| upsTrapAlarmAwaitingPowerRestoredeighth A awaiting power condition is restored (*). | notification | - | .1.3.6.1.4.1.818.1.1.18.11.53 |
| upsTrapAlarmShutdownPendingRestoredeighth A upsShutdownAfterDelay countdown is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.54 |
| upsTrapAlarmShutdownImminentRestoredeighth A shutdown imminent condition is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.55 |
| upsTrapAlarmTestInProgressRestoredeighth The test is in progress is terminated. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.56 |
| upsTrapAlarmReceptacleOneighth A receptacle has been switched on. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.57 |
| upsTrapAlarmHighspeedBusRestoreeighth A problem on the Highspeed Bus communication is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.58 |
| upsTrapAlarmHighspeedBusJACRCRestoreeighth A CRC failure on the Highspeed Bus JA is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.59 |
| upsTrapAlarmInputBadeighth An input condition is out of tolerance. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.6 |
| upsTrapAlarmConnectivityBusRestoreeighth A problem on the Connectivity Bus communication is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.60 |
| upsTrapAlarmHighspeedBusJBCRCRestoredeighth A CRC failure on the Highspeed Bus JB is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.61 |
| upsTrapAlarmCurrentSharingRestoredeighth An high current sharing on the parallel system is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.62 |
| upsTrapAlarmDCRippleRestoredeighth An high ripple voltage on his DC link is restored. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.63 |
| upsTrapAlarmOutputBadeighth An output condition (other than OutputOverload) is
out of tolerance. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.7 |
| upsTrapAlarmOutputOverloadeighth The output load exceeds the UPS output capacity. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.8 |
| upsTrapAlarmOnBypasseighth The Bypass is presently engaged on the UPS. | notification | - | .1.3.6.1.4.1.818.1.1.18.11.9 |