upsIdent
GEPARALLELUPS-MIB ·
.1.3.6.1.4.1.818.1.1.10.1
Object
node
No description available.
Context
- MIB
- GEPARALLELUPS-MIB
- OID
.1.3.6.1.4.1.818.1.1.10.1- Type
- node
- Parent
- geGenericUPS
- Siblings
- 11
- Children
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsGetSet | node | - | .1.3.6.1.4.1.818.1.1.10.10 |
| geUPSTraps | node | - | .1.3.6.1.4.1.818.1.1.10.11 |
| upsDiagnostic | node | - | .1.3.6.1.4.1.818.1.1.10.12 |
| upsBattery | node | - | .1.3.6.1.4.1.818.1.1.10.2 |
| upsInput | node | - | .1.3.6.1.4.1.818.1.1.10.3 |
| upsOutput | node | - | .1.3.6.1.4.1.818.1.1.10.4 |
| upsBypass | node | - | .1.3.6.1.4.1.818.1.1.10.5 |
| upsAlarm | node | - | .1.3.6.1.4.1.818.1.1.10.6 |
| upsTest | node | - | .1.3.6.1.4.1.818.1.1.10.7 |
| upsControl | node | - | .1.3.6.1.4.1.818.1.1.10.8 |
| upsConfig | node | - | .1.3.6.1.4.1.818.1.1.10.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsIdentManufacturer The name of the UPS manufacturer.(*) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.10.1.1 |
| upsIdentModel The UPS Model designation.(*) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.10.1.2 |
| upsIdentUPSSoftwareVersion The UPS firmware/software version(s). This variable
may or may not have the same value as
upsIdentAgentSoftwareVersion in some implementations.(*) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.10.1.3 |
| upsIdentAgentSoftwareVersion The UPS agent software version. This variable may or
may not have the same value as
upsIdentUPSSoftwareVersion in some implementations.(*) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.10.1.4 |
| upsIdentName A string identifying the UPS. This object should be
set by the administrator.(*) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.10.1.5 |
| upsIdentAttachedDevices A string identifying the devices attached to the
output(s) of the UPS. This object should be set by
the administrator.(*) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.10.1.6 |
| upsIdentUPSSerialNumber The UPS serial number | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.10.1.7 |
| upsIdentComProtVersion The IMV communication protocol version | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.10.1.8 |
| upsIdentOperatingTime The present value of the operating time.
total 'on' time since UPS manufactured | scalar | seconds NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.10.1.9 |