upsDiagnosticBusJBCommunicationStatussixth
GEPARALLELUPS-MIB ·
.1.3.6.1.4.1.818.1.1.16.12.2
Object
scalar
SNMPv2-SMIInteger32
Bit oriented values associated to the ID of the UPS (bit0 = UPS1 ... bit7 = UPS8). The correspondent UPS is not present on the high speed bus communication JA if bit=0.(*)
Context
- MIB
- GEPARALLELUPS-MIB
- OID
.1.3.6.1.4.1.818.1.1.16.12.2- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- upsDiagnosticsixth
- Siblings
- 6
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsDiagnosticBusJACommunicationStatussixth Bit oriented values associated to the ID of the UPS
(bit0 = UPS1 ... bit7 = UPS8).
The correspondent UPS is not present on the high speed
bus communication JA if bit=0.(*) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.818.1.1.16.12.1 |
| upsDiagnosticBatteryLifetimesixth The critical components are associated to Service
parameters indicating the remaining lifetime.
They are initially set to default values depending
to the data given by the comp… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.818.1.1.16.12.3 |
| upsDiagnosticFansLifetimesixth The critical components are associated to Service
parameters indicating the remaining lifetime.
They are initially set to default values depending
to the data given by the comp… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.818.1.1.16.12.4 |
| upsDiagnosticDCcapacitorsLifetimesixth The critical components are associated to Service
parameters indicating the remaining lifetime.
They are initially set to default values depending
to the data given by the comp… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.818.1.1.16.12.5 |
| upsDiagnosticACcapacitorsLifetimesixth The critical components are associated to Service
parameters indicating the remaining lifetime.
They are initially set to default values depending
to the data given by the comp… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.818.1.1.16.12.6 |
| upsDiagnosticGlobalServiceChecksixth The critical components are associated to Service
parameters indicating the remaining lifetime.
They are initially set to default values depending
to the data given by the comp… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.818.1.1.16.12.7 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsOutputNumLinessixth The number of output lines utilized in this device.
This variable indicates the number of rows in the
output table.(*) | scalar | NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.16.4.3 |
| upsOutputPercentLoadsixth The percentage of the UPS power capacity presently
being used on this output line, i.e., the greater of
the percent load of true power capacity and the
percent load of VA.(*) | column | percent Integer32 | .1.3.6.1.4.1.818.1.1.16.4.4.1.5 |