upsConfigBatteryCapacitythird
GEPARALLELUPS-MIB ·
.1.3.6.1.4.1.818.1.1.13.9.11
Object
scalar
r/w
Amps Hours NonNegativeInteger32
The installed battery capacity. This value is the 'factory'-value, not the value after calibration.
Context
- MIB
- GEPARALLELUPS-MIB
- OID
.1.3.6.1.4.1.818.1.1.13.9.11- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- Amps Hours
- Parent
- upsConfigthird
- Siblings
- 13
Syntax
Amps Hours NonNegativeInteger32
- Source
- NonNegativeInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: 0..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsConfigInputVoltagethird The magnitude of the nominal input voltage. On those
systems which support read-write access to this
object, if there is an attempt to set this variable to
a value that is not su… | scalar | RMS Volts NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.13.9.1 |
| upsConfigHighVoltageTransferPointthird The maximum line voltage allowed before the UPS
system transfers to battery backup.(*) | scalar | RMS Volts NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.13.9.10 |
| upsConfigBatteryChargeCurrentthird The maximum battery charge current, including external chargers. | scalar | 0.1 Amp DC NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.13.9.12 |
| upsConfigNoLoadShutdownthird Dis- or enable 'no load' shutdown from the contact interface. | scalar | Enumeration | .1.3.6.1.4.1.818.1.1.13.9.13 |
| upsConfigStartDelaythird Minimum required autonomy time before the UPS may perform an
autorestart. | scalar | minutes PositiveInteger32 | .1.3.6.1.4.1.818.1.1.13.9.14 |
| upsConfigInputFreqthird The nominal input frequency. On those systems which
support read-write access to this object, if there is
an attempt to set this variable to a value that is not
supported, the re… | scalar | 0.1 Hertz NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.13.9.2 |
| upsConfigOutputVoltagethird The magnitude of the nominal output voltage. On
those systems which support read-write access to this
object, if there is an attempt to set this variable to
a value that is not s… | scalar | RMS Volts NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.13.9.3 |
| upsConfigOutputFreqthird The nominal output frequency. On those systems which
support read-write access to this object, if there is
an attempt to set this variable to a value that is not
supported, the r… | scalar | 0.1 Hertz NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.13.9.4 |
| upsConfigOutputVAthird The magnitude of the nominal Volt-Amp rating.(*) | scalar | Volt-Amps NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.13.9.5 |
| upsConfigOutputPowerthird The magnitude of the nominal true power rating.(*) | scalar | Watts NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.13.9.6 |
| upsConfigLowBattTimethird The value of upsEstimatedMinutesRemaining at which a
lowBattery condition is declared. For agents which
support only discrete (discontinuous) values, then the
agent shall round u… | scalar | minutes NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.13.9.7 |
| upsConfigAudibleStatusthird The requested state of the audible alarm. When in
the disabled state, the audible alarm should never
sound. The enabled state is self-describing. Setting
this object to muted(3… | scalar | Enumeration | .1.3.6.1.4.1.818.1.1.13.9.8 |
| upsConfigLowVoltageTransferPointthird The minimum input line voltage allowed before the UPS
system transfers to battery backup.(*) | scalar | RMS Volts NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.13.9.9 |