cmgPowerMgProcessor
G700-MG-MIB ·
.1.3.6.1.4.1.6889.2.9.1.1.10.7
Object
scalar
SNMPv2-SMIInteger32
Voltage reading in millivolts at the power supply serving the Media Gateway main processor. Nominal value is +5100 mV. If the reading falls outside the range 4950 to 5250 mV, a trap is sent to the management console and the corresponding bit in the fault mask is turned on.
Context
- MIB
- G700-MG-MIB
- OID
.1.3.6.1.4.1.6889.2.9.1.1.10.7- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- cmgHardware
- Siblings
- 13
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cmgCpuTemp Reading of the internal temperature sensor at the CPU,
expressed in degrees Celsius. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6889.2.9.1.1.10.1 |
| cmgPowerDsp Voltage reading in millivolts at the power supply serving the DSP
units, derived from VoIP complex power. Nominal value is +1580 mV.
If the reading falls outside the range 1530 t… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6889.2.9.1.1.10.10 |
| cmgPower8260 Voltage reading in millivolts at the power supply serving the 8260
processor, derived from VoIP complex power. Nominal value is +2500
mV. If the reading falls outside the range … | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6889.2.9.1.1.10.11 |
| cmgHardwareFaultMask Each bit of this value set to '1' indicates a specific fault
in the module.
Octets are numbered in the order in which they appear in the PDU.
Bits are numbered from the… | scalar | OctetString | .1.3.6.1.4.1.6889.2.9.1.1.10.12 |
| cmgHardwareStatusMask Each bit of this value set to '1' indicates a specific status
condition in the module.
Octets are numbered in the order in which they appear in the PDU.
Bits are number… | scalar | OctetString | .1.3.6.1.4.1.6889.2.9.1.1.10.13 |
| cmgHardwareFanLowSpeedLevel The fan speed level mode. Disable(2) is used for normal operation of two fan speeds.
Enable(1) is used to activate additional lower speed level.
Default is disable(2). | scalar | Enumeration | .1.3.6.1.4.1.6889.2.9.1.1.10.14 |
| cmgCpuTempWarningThresh Internal enclosure temperature warning threshold, expressed in degrees
Celsius. When the temperature at the CPU sensor exceeds the threshold,
a trap is sent to the management con… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6889.2.9.1.1.10.2 |
| cmgCpuTempShutdownThresh Internal enclosure temperature shutdown threshold, expressed in degrees
Celsius. When the temperature at the CPU sensor exceeds the threshold,
a trap is sent to the management co… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6889.2.9.1.1.10.3 |
| cmgDspTemp Reading of the internal temperature sensor at the DSPs,
expressed in degrees Celsius. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6889.2.9.1.1.10.4 |
| cmgDspTempWarningThresh Internal enclosure temperature warning threshold, expressed in degrees
Celsius. When the temperature at the DSP sensor exceeds the threshold,
a trap is sent to the management con… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6889.2.9.1.1.10.5 |
| cmgDspTempShutdownThresh Internal enclosure temperature shutdown threshold, expressed in degrees
Celsius. When the temperature at the DSP sensor exceeds the threshold,
a trap is sent to the management co… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6889.2.9.1.1.10.6 |
| cmgPowerMediaModules Voltage reading in millivolts at the power supply serving the Media
Modules. Nominal value is -48000 mV. If the reading falls outside
the range -43000 to -53000 mV, a trap is se… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6889.2.9.1.1.10.8 |
| cmgPowerVoipComplex Voltage reading in millivolts at the power supply serving the VoIP
complexes. Nominal value is +3400 mV. If the reading falls outside
the range 3200 to 3600 mV, a trap is sent t… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6889.2.9.1.1.10.9 |