cmgModuleStatusMask
G700-MG-MIB ·
.1.3.6.1.4.1.6889.2.9.1.1.11.1.1.11
Object
column
OctetString
Each bit of this value set to '1' indicates a specific status
condition in the module.
Octets are numbered in the order in which they appear in the PDU.
Bits are numbered from the most-significant leftmost bit in the
octet (bit 0) to the least-significant rightmost bit (bit 7).
Cajun numbering continues across octets, so that octet 1 bit 0 is
called bit 8 in the Cajun scheme. That number is also shown below,
with the octet value for each single bit set.
Cajun Octet Octet
bit# bit# value Meaning
----- ----- ----- -------
0 0/0 0x80 Red LED is on.
1 0/1 0x40 Module controlled by ACP on communications controller.
2-7 0/2-7 Unused.
8-15 1/0-7 Unused.
Context
- MIB
- G700-MG-MIB
- OID
.1.3.6.1.4.1.6889.2.9.1.1.11.1.1.11- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cmgModuleEntry
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-2