cmgModuleStatusMask

G700-MG-MIB · .1.3.6.1.4.1.6889.2.9.1.1.11.1.1.11

Object

column OctetString
Each bit of this value set to '1' indicates a specific status
condition in the module.
              
Octets are numbered in the order in which they appear in the PDU.
Bits are numbered from the most-significant leftmost bit in the
octet (bit 0) to the least-significant rightmost bit (bit 7).
              
Cajun numbering continues across octets, so that octet 1 bit 0 is
called bit 8 in the Cajun scheme.  That number is also shown below,
with the octet value for each single bit set.
              
Cajun  Octet Octet
bit#   bit#  value	Meaning
-----  ----- -----	-------
0      0/0   0x80	Red LED is on.
1      0/1   0x40	Module controlled by ACP on communications controller.
2-7    0/2-7	Unused.
8-15   1/0-7	Unused.

Context

MIB
G700-MG-MIB
OID
.1.3.6.1.4.1.6889.2.9.1.1.11.1.1.11
Type
column
Access
readonly
Status
current
Parent
cmgModuleEntry
Table
cmgModuleTable
Siblings
12

Syntax

OctetString

Values & Constraints

Object Constraints
range: 0-2

Related Objects

Sibling Objects