cmgModuleFaultMask
G700-MG-MIB ·
.1.3.6.1.4.1.6889.2.9.1.1.11.1.1.10
Object
column
OctetString
Each bit of this value set to '1' indicates a specific fault
in the module.
Octets are numbered in the order in which they appear in the PDU.
Bits are numbered from the most-significant leftmost bit in the
octet (bit 0) to the least-significant rightmost bit (bit 7).
Cajun numbering continues across octets, so that octet 1 bit 0 is
called bit 8 in the Cajun scheme. That number is also shown below,
with the octet value for each single bit set.
Cajun Octet Octet
bit# bit# value Meaning
----- ----- ----- -------
0 0/0 0x80 Media module is in administrative busy-out.
1 0/1 0x40 One or more ports on this media module is in administrative
busy-out.
2 0/2 0x20 Insertion sequence failed.
3 0/3 AWOH data module conflict.
4 0/4 0x08 Media module automatic reset occurred.
5 0/5 0x04 One or more power-on startup tests failed.
6 0/6 0x02 Media module parameter exchange failed.
7 0/7 Unsupported module enrolment.
8-15 1/0-7 Unused.
Context
- MIB
- G700-MG-MIB
- OID
.1.3.6.1.4.1.6889.2.9.1.1.11.1.1.10- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cmgModuleEntry
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-2