x2gConfigCrossConnect
G6-MSP1000-MIB ·
.1.3.6.1.4.1.3181.10.6.1.94.3.1.6
Object
column
r/w
Enumeration
This parameter defines the data path through the module. It is also used to setup a permanent bit error rate test.
Context
- MIB
- G6-MSP1000-MIB
- OID
.1.3.6.1.4.1.3181.10.6.1.94.3.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- x2gConfigEntry
- Table
- x2gConfigTable
- Siblings
- 19
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | disconnect |
1 | alternate |
5 | backup |
9 | ringBackupWest |
11 | multicast |
12 | dropContinue |
13 | addDropWest |
14 | addDropEast |
15 | ringBackupEast |
16 | crossOver |
17 | switchP1P2 |
18 | switchP1P3 |
19 | switchP1P4 |
20 | normal |
21 | bertPort4 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| x2gConfigIndex Automatically generated | column | Integer32 | .1.3.6.1.4.1.3181.10.6.1.94.3.1.1 |
| x2gConfigDeactivatePort4 When enabled, the optical interface is disabled and communication is cut. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.10 |
| x2gConfigFrontPanelMode Determines what is displayed on the front panel, when available. Also controls the modules local buttons. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.11 |
| x2gConfigLossOfSignalHandling When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the currently associated port. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.12 |
| x2gConfigOptimizedFor8b10b Enable this feature when Ethernet or FibreChannel is used. Do not set when SDH is used on any port. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.13 |
| x2gConfigBertPattern Defines the bit pattern with which the build-in bit error rate tester (BERT) operates when cross connect is set to BERT. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.14 |
| x2gConfigSfpDeltaInterval This enables and defines the interval in which the optical receive power level of each SFP is read and compared to previous value. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.15 |
| x2gConfigSfpDeltaThreshold This defines how much the optical receive power level can differ between successive reads before a warning trap is generated. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.16 |
| x2gConfigBackupTrigger Defines under which optical signal condition an automated backup is initiated. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.17 |
| x2gConfigStayWithLastLink When set the backup switch remains in last position even when signal returns. Still the backup warning turns off after the delay set under backup_end parameter expires. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.18 |
| x2gConfigBackupEnd Defines how long the signal must remain steady before proper operation is assumed and the backup is terminated. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.19 |
| x2gConfigPort1Datarate This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.2 |
| x2gConfigPermitLinkOverride Permits the manual selection of a failed link using the link selection. Defaults to false to safeguard against accidential link selection which would result in loss of connection. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.20 |
| x2gConfigPort2Datarate This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.3 |
| x2gConfigPort3Datarate This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.4 |
| x2gConfigPort4Datarate This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.5 |
| x2gConfigDeactivatePort1 When enabled, the optical interface is disabled and communication is cut. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.7 |
| x2gConfigDeactivatePort2 When enabled, the optical interface is disabled and communication is cut. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.8 |
| x2gConfigDeactivatePort3 When enabled, the optical interface is disabled and communication is cut. | column | Enumeration | .1.3.6.1.4.1.3181.10.6.1.94.3.1.9 |