syncELockedQuality
FS-SWITCH-MIB ·
.1.3.6.1.4.1.27975.81.6
Object
scalar
Enumeration
Get the locked quality.The meanings of the values are:
prs(1) - PRS traceable (ITU-T G.811);
prc(2) - Primary reference clock;
stu(3) - Synchronized Ƀ Traceability unknown;
ssua(4) - Type I or V slave clock
defined in ITU-T G.812;
tnc(5) - Traceable to transit node clock
(ITU-T G.812, type V);
st2(6) - Traceable to stratum 2
(ITU-T G.812, type II);
ssub(7) - Type VI slave clock defined in ITU-T G.812;
eec2(8) - EEC2 clock or st3 clock;
eec1(9) - EEC1 clock or SEC clock;
smc(10) - Traceable to SONET clock self timed;
st3e(11) - Traceable to stratum 3E
(ITU-T G.812, type III);
prov(12) - Provisionable by the network operator;
dnu(13) - Do not use this quality;
dus(14) - Do not use for synchronization
Context
- MIB
- FS-SWITCH-MIB
- OID
.1.3.6.1.4.1.27975.81.6- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- syncE
- Siblings
- 14
Syntax
Enumeration
Values & Constraints
Object Constraints
range: 0-65535
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| syncEDeviceClockID A exclusive flag to distinguish every device | scalar | OctetString | .1.3.6.1.4.1.27975.81.1 |
| syncEClockState Get the device clock status.
The meanings of the values are:
master-clock(1) - Master-only device
affords time signal;
freerun(2) - Device has not been … | scalar | Enumeration | .1.3.6.1.4.1.27975.81.10 |
| syncENotifications | node | - | .1.3.6.1.4.1.27975.81.100 |
| syncEOptionMode Get the device clock ssm option mode.
op1(1) - Option mode 1;
op2(2) - Option mode 2 | scalar | Enumeration | .1.3.6.1.4.1.27975.81.11 |
| syncESwitchForceIF Switch time resource to one interface forcibaly.
The value is the ifindex.
Value 0 cancles configuration | scalar | Integer32 | .1.3.6.1.4.1.27975.81.12 |
| syncEIfTable Table of ssm interface entry. | table | - | .1.3.6.1.4.1.27975.81.13 |
| syncEClockRecoverySelect Set the way to recovery clock.
The meanings of the values are:
synce(1) - Set syncE to recovery clock;
bits1(2) - Set bits1 to recovery clock;
bits2(3) - Set bits2 to recov… | scalar | Enumeration | .1.3.6.1.4.1.27975.81.15 |
| syncEGlbEnable Set whether the device is a synchronous equipment.
The meanings of the values are:
enable(1) - A synchronous equipment;
disable(2) - Not a synchronous equipment | scalar | Enumeration | .1.3.6.1.4.1.27975.81.2 |
| syncESsmGlbEnable Set whether the device work under synchronous
operation mode. The meanings of the values are:
enable(1) - Under synchronous operation mode;
disable(2) - Under non-sync operati… | scalar | Enumeration | .1.3.6.1.4.1.27975.81.3 |
| syncEDeviceType Set the device type. The meanings of the values are:
master-olny(1) - master-only type;
slave-only(2) - slave-only type;
none(3) - default type | scalar | Enumeration | .1.3.6.1.4.1.27975.81.4 |
| syncELocalQuality Set the device quality globally under option1.
The meanings of the values are:
op2-prs(1) - Primary reference source;
op1-prc(2) - Primary reference clock;
op2-eec2(3) - EEC2… | scalar | Enumeration | .1.3.6.1.4.1.27975.81.5 |
| syncELocalPriority Set the device priority globally.
The range is 1 ~ 255 | scalar | Integer32 | .1.3.6.1.4.1.27975.81.7 |
| syncESelectedInterface Get ifindex of the current selected port.
0 means no interface is selected. | scalar | Integer32 | .1.3.6.1.4.1.27975.81.8 |
| syncEExtensionEnable Set whether the device start extend ssm.
The meanings of the values are:
enable(1) - Start extend ssm;
disable(2) - Not start extend ssm | scalar | Enumeration | .1.3.6.1.4.1.27975.81.9 |