flWorkNetPortPofScrjIfStatus
FL-MGD-INFRASTRUCT-MIB ·
.1.3.6.1.4.1.4346.11.11.4.2.4.1.2
Object
column
Enumeration
This delivers the current status of the POF SCRJ interface
on the selected port. Meanings are:
notSupported(1) = The actual hw does not support POF SCRJ interface diagnostics.
Plugged modules will transmit and receive data but the user will
not be able to read out any diagnostic data.
noModule(2) = No POF SCRJ hardware on this port.
ok(3), = An POF SCRJ hardware is present, rx power is ok.
systemReserveLow(4), = An POF SCRJ hardware is present, link is ok but rx light power is low.
Data transmission is endangered if light power decreases. (System reserver < 2 dB)
systemReserveExhausted(5) = An POF SCRJ hardware is present, link is ok but rx light power is very low.
Data transmission is most probably not possible any more. (Rx power low)
Context
- MIB
- FL-MGD-INFRASTRUCT-MIB
- OID
.1.3.6.1.4.1.4346.11.11.4.2.4.1.2- Type
- column
- Access
- readonly
- Status
- current
- Parent
- flWorkNetPortPofScrjIfEntry
- Table
- flWorkNetPortPofScrjIfTable
- Siblings
- 17
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| flWorkNetPortPofScrjIfIndex This object identifies the port. This value
is never greater then flWorkNetPortCapacity. | column | Integer32 | .1.3.6.1.4.1.4346.11.11.4.2.4.1.1 |
| flWorkNetPortPofScrjIfRxPowerLowAlarm Deliverst if the Rx power low alarm for a given port is
set (present(2)) or not set (notPresent(1)) | column | Enumeration | .1.3.6.1.4.1.4346.11.11.4.2.4.1.10 |
| flWorkNetPortPofScrjIfRxPowerHighWarning Deliverst if the Rx power high warning for a given port is
set (present(2)) or not set (notPresent(1)) | column | Enumeration | .1.3.6.1.4.1.4346.11.11.4.2.4.1.11 |
| flWorkNetPortPofScrjIfRxPowerLowWarning Delivers if the Rx power low warning for a given port is
set (present(2)) or not set (notPresent(1)) | column | Enumeration | .1.3.6.1.4.1.4346.11.11.4.2.4.1.12 |
| flWorkNetPortPofScrjIfManufacturer Delivers the name of the manufacturer that
did produce the POF SCRJ transceiver device
on the given port | column | OctetString | .1.3.6.1.4.1.4346.11.11.4.2.4.1.13 |
| flWorkNetPortPofScrjIfManufactOui Delivers the IEEE manufacturer ID of the
manufacturer that did produce the POF SCRJ
transceiver device on the given port | column | OctetString | .1.3.6.1.4.1.4346.11.11.4.2.4.1.14 |
| flWorkNetPortPofScrjIfRevision Delivers the revision of the POF SCRJ
transceiver device on the given port | column | OctetString | .1.3.6.1.4.1.4346.11.11.4.2.4.1.16 |
| flWorkNetPortPofScrjIfWavelength Delivers the wavelength in units of nm the POF SCRJ
transceiver device on the given port is using for signal
generation | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4346.11.11.4.2.4.1.17 |
| flWorkNetPortPofScrjIfTransceiverOptions Gives detailed informations about the
implemented features of th POF SCRJ transceiver
on the given port.
You have to take a look at the binary representation
of the returned num… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4346.11.11.4.2.4.1.18 |
| flWorkNetPortPofScrjIfSerialNumber Delivers the serial number of the POF SCRJ
transceiver device on the given port | column | OctetString | .1.3.6.1.4.1.4346.11.11.4.2.4.1.19 |
| flWorkNetPortPofScrjIfDatecodeAndLot Delivers the manufacturing date an lot number of
the POF SCRJ transceiver on the given port.
BYTE 1 + 2: Year
BYTE 3 + 4: MONTH
BYTE 5 + 6: DAY
BYTE 7 + 8: LOT Number | column | OctetString | .1.3.6.1.4.1.4346.11.11.4.2.4.1.20 |
| flWorkNetPortPofScrjIfAlarmContactEnable If this object is switched to enable
the alarm contact will open if this
POF SCRJ transceiver reaches a critical
RX power state.
See object
flWorkFWCtrlAlarmContactEventPoFScrjTr… | column | Enumeration | .1.3.6.1.4.1.4346.11.11.4.2.4.1.21 |
| flWorkNetPortPofScrjIfSupplyVoltage Delivers the actual supply voltage of the
transceiver device on the given port
in 0.1 Volt. (i.e. range is von 0 to 6,5V) | column | Integer32 | .1.3.6.1.4.1.4346.11.11.4.2.4.1.4 |
| flWorkNetPortPofScrjIfTxPower Delivers the actual transmission power of the
transceiver device on the given port
in 0.1uW. (i.e. range is von 0 to 0,006553 W) | column | Integer32 | .1.3.6.1.4.1.4346.11.11.4.2.4.1.6 |
| flWorkNetPortPofScrjIfRxPower Delivers the actual reception power of the
transceiver device on the given port
in 0.1uW. (i.e. range is von 0 to 0,006553 W) | column | Integer32 | .1.3.6.1.4.1.4346.11.11.4.2.4.1.7 |
| flWorkNetPortPofScrjIfSystemReserve Delivers the remaining system reserve in units of 0.1dB | column | Integer32 | .1.3.6.1.4.1.4346.11.11.4.2.4.1.8 |
| flWorkNetPortPofScrjIfRxPowerHighAlarm Deliverst if the Rx power high alarm for a given port is
set (present(2)) or not set (notPresent(1)) | column | Enumeration | .1.3.6.1.4.1.4346.11.11.4.2.4.1.9 |