flWorkNetPortPoeFaultMonitoring
FL-MGD-INFRASTRUCT-MIB ·
.1.3.6.1.4.1.4346.11.11.4.2.3.1.8
Object
column
r/w
Enumeration
This object can be set to 'enable' if the user wants any error
concerning an PoE module on this port to be monitored. If errors
are monitored and if any malfunctions concerning PoE are detected on
this port they will cause the display of the device to show
an error code and will cause the alarm contact to open
if the contact is configured that way (see MIB-group flWorkFWCtrlAlarmContactEvents).
disable(1) = errors are not monitored
enable(2) = errors are monitored
Context
- MIB
- FL-MGD-INFRASTRUCT-MIB
- OID
.1.3.6.1.4.1.4346.11.11.4.2.3.1.8- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- flWorkNetPortPoEEntry
- Table
- flWorkNetPortPoETable
- Siblings
- 7
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| flWorkNetPortPoEIndex This object identifies the port. This value
is never greater then flWorkNetPortCapacity. | column | Integer32 | .1.3.6.1.4.1.4346.11.11.4.2.3.1.1 |
| flWorkNetPortPoEPowerEnable Get back or set the current state of the PoE
device on this port.
enabled(1) = power on this port is/should be enabled
disabled(2) = power on this port is/should be disabled
unkn… | column | Enumeration | .1.3.6.1.4.1.4346.11.11.4.2.3.1.2 |
| flWorkNetPortPoECurrentLimitation Get back or set the current limitation state of the PoE
device on this port.
on(1) = limits output current to 90mA if a class 1 device is connected
off(2) = current is … | column | Enumeration | .1.3.6.1.4.1.4346.11.11.4.2.3.1.3 |
| flWorkNetPortPoEDeviceClass Get back the device class type of the device connected to
this port or recently connected to this port.
class0(0)
class1(1)
class2(2)
class3(3)
class4(4)
Device class unknown(5) | column | Enumeration | .1.3.6.1.4.1.4346.11.11.4.2.3.1.4 |
| flWorkNetPortPoEOutputCurrent Get back output current in mA actually delivered on this port | column | Integer32 | .1.3.6.1.4.1.4346.11.11.4.2.3.1.5 |
| flWorkNetPortPoEOutputVoltage Get back output voltage in mV actually delivered on this port | column | Integer32 | .1.3.6.1.4.1.4346.11.11.4.2.3.1.6 |
| flWorkNetPortPoEFaultStatus Get back the fault status of the PoE device on this port
noFault(0) = no fault status detected at all
voltage(1) = external supply voltage fault
thermal… | column | Enumeration | .1.3.6.1.4.1.4346.11.11.4.2.3.1.7 |