flWorkNetPortPoEFaultStatus

FL-MGD-INFRASTRUCT-MIB · .1.3.6.1.4.1.4346.11.11.4.2.3.1.7

Object

column Enumeration
Get back the fault status of the PoE device on this port
noFault(0)              = no fault status detected at all
voltage(1)              = external supply voltage fault 
thermal(2)              = over temperature
overload(3)             = overload (current limitation active?)
loadDisconnected(4)     = load has been disconnected  
powerSupplyMissing(5)   = PoE controller not responding. 48V supply missing?
noPse(6)                = No PSE interface module has been plugged on this port
noPoeSupport(7)         = Switch device does not support PoE devices e.g. because of 
                          unsufficient hardware revision. 
noPoeDeviceConnected(8) = No PoE enabled powered device has been externally 
                          connected to this PoE port

Context

MIB
FL-MGD-INFRASTRUCT-MIB
OID
.1.3.6.1.4.1.4346.11.11.4.2.3.1.7
Type
column
Access
readonly
Status
current
Parent
flWorkNetPortPoEEntry
Table
flWorkNetPortPoETable
Siblings
7

Syntax

Enumeration

Values & Constraints

No enumerated values or constraints recorded.