snAgentPoePortConsumed
FDRY-POE-MIB ·
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.6
Object
column
SNMPv2-SMIInteger32
Inline power consumed by the port. Each unit is milliwatts.
Context
- MIB
- FDRY-POE-MIB
- OID
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.6- Type
- column
- Access
- readonly
- Status
- current
- Parent
- snAgentPoePortEntry
- Table
- snAgentPoePortTable
- Siblings
- 15
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| snAgentPoePortNumber The port number in ifIndex value. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.1 |
| snAgentPoePortlldpReqPwr Maximum power requested by PD through LLDP in milliwatts. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.10 |
| snAgentPoePortlldpReqPwrA deprecated Maximum power requested by PD through LLDP in milliwatts. In case of Dual Signature PD we have 2 channel
snAgentPoePortlldpReqPwrA is power in milliwatts for channel A.
This is de… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.11 |
| snAgentPoePortlldpReqPwrB deprecated Maximum power requested by PD through LLDP in milliwatts. In case of Dual Signature PD we have 2 channel
snAgentPoePortlldpReqPwrB is power in milliwatts for channel B.
This is de… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.12 |
| snAgentPoePortCapability Capability of port, 0-others, 1-2pair, 2-4pair. | column | Enumeration | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.13 |
| snAgentPoePortMax2PairPwr Maximum power supported by 2pair port in milliwatts. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.14 |
| snAgentPoePortMax4PairPwr Maximum power supported by 4pair port in milliwatts. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.15 |
| snAgentPoePortMode Poe port overdrive mode. | column | Enumeration | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.16 |
| snAgentPoePortControl Control inline power on/off to a port. If a port does not
have inline power capability, reading this object returns
'other(1)'. | column | Enumeration | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.2 |
| snAgentPoePortWattage Adjust the inline power wattage. Valid value between 1000
to 15400(IEEE802_3AF)/30000(IEEE802_3AT)/120000(IEEE802_3BT). Each unit is milliwatts.
This object can only be set after … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.3 |
| snAgentPoePortClass Adjust the inline power class. Valid value between 0 to 3(IEEE802_3AF)/4(IEEE802_3AT).
This object can only be set after snSwIfInLinePowerControl
has been set to 'enable(3)' or 'e… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.4 |
| snAgentPoePortPriority Inline power allocation priority for the power device
0- Not a POE port, 1- Critical, 2- High, 3- Low,
4- Medium, 5- other. | column | Enumeration | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.5 |
| snAgentPoePortType Inline Power device type 802.3af, 802.3at, 802.3bt or Legacy device. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.7 |
| snAgentPoePortPDClass This is a PD signature which the decive learns in the process of
PD-classification. PD detection and PD-classification are two steps of powering PD.
And if PD is powered without… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.8 |
| snAgentPoePortPDClassB This is second PD class signature of dual signature PD which the device learns in the process of
PD-classification. PD detection and PD-classification are two steps of powering P… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1991.1.1.2.14.2.2.1.9 |