connUnitGlobalId
FCMGMT-MIB ·
.1.3.6.1.3.94.1.6.1.2
Object
column
mandatory
FcGlobalId
An optional global-scope identifier for this connectivity unit.
It MUST be a WWN for this connectivity unit
or 16 octets of value zero.
WWN formats requiring fewer than 16 octets
MUST be extended to 16 octets with trailing zero octets,
Left justified, zero filled,
If a WWN is used for connUnitId,
the same WWN MUST be used for connUnitGlobalId.
When a non-zero value is provided,
it SHOULD be persistent across agent and unit resets.
It SHOULD be globally unique.
It SHOULD be one of these FC-PH/PH3 formats:
IEEE (NAA=1)
IEEE Extended (NAA=2)
IEEE Registered (NAA=5).
IEEE Registered extended (NAA=6).
Use of the IEEE formats allows any IEEE-registered vendor
to assure global uniqueness independently.
The following are some references on IEEE WWN formats:
http://standards.ieee.org/regauth/oui/tutorials/fibreformat.html
http://standards.ieee.org/regauth/oui/tutorials/fibrecomp_id.html
If one or more WWNs are associated with the connUnit
via other management methods,
one of them SHOULD be used for connUnitGlobalId.
If there is not a WWN assigned specifically to the connUnit,
there is some merit, though not a requirement,
to using a WWN assigned to (one of)
its permanently attached FC/LAN interface(s).
This can not risk uniqueness, though.
As a counterexample, if your
agent runs in a host and the host has an HBA,
it is quite possible that agent, host, and HBA
will all be distinct connUnits, so the host
and agent can not use the WWN of the HBA.
Another example:
If your hub has a built-in Ethernet port, it
might be reasonable for the hub to use its MAC
address (prefixed with the appropriate
NAA) as its connUnitId. But if the
Ethernet were a replaceable PCCard, the hub
should have an independent ID.
Context
- MIB
- FCMGMT-MIB
- OID
.1.3.6.1.3.94.1.6.1.2- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- connUnitEntry
- Table
- connUnitTable
- Siblings
- 30
Syntax
FcGlobalId
- Source
- FcGlobalId
- Base type
OctetString
Values & Constraints
Type Constraints
range: 16
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| connUnitId mandatory The unique identification for this connectivity unit
among those within this proxy domain.
The value MUST be unique within the proxy domain
because it is the index variable for … | column | FcGlobalId | .1.3.6.1.3.94.1.6.1.1 |
| connUnitUrl mandatory URL to launch a management application,
if applicable. Otherwise empty string.
In a standalone unit, this would be the
same as the top-level URL. This has the same
definition a… | column | RFC1213-MIBDisplayString | .1.3.6.1.3.94.1.6.1.10 |
| connUnitDomainId mandatory 24 bit Fibre Channel address ID of this
connectivity unit, right justified with leading
zero's if required. This should be set to the
Fibre Channel address ID or if it is a swit… | column | OctetString | .1.3.6.1.3.94.1.6.1.11 |
| connUnitProxyMaster mandatory A value of 'yes' means this is the proxy master
unit for a set of managed units. For example,
this could be the only unit with a management
card in it for a set of units. A sta… | column | Enumeration | .1.3.6.1.3.94.1.6.1.12 |
| connUnitPrincipal mandatory Whether this connectivity unit is the principal unit
within the group of fabric elements. If this value
is not applicable, return unknown. | column | Enumeration | .1.3.6.1.3.94.1.6.1.13 |
| connUnitNumSensors mandatory Number of sensors in the connUnitSensorTable. | column | Integer32 | .1.3.6.1.3.94.1.6.1.14 |
| connUnitStatusChangeTime obsolete The sysuptime timestamp in centiseconds
at which the last status change occurred. | column | RFC1155-SMITimeTicks | .1.3.6.1.3.94.1.6.1.15 |
| connUnitConfigurationChangeTime obsolete The sysuptime timestamp in centiseconds
at which the last configuration change
occurred. | column | RFC1155-SMITimeTicks | .1.3.6.1.3.94.1.6.1.16 |
| connUnitNumRevs mandatory The number of revisions in the connUnitRevsTable. | column | Integer32 | .1.3.6.1.3.94.1.6.1.17 |
| connUnitNumZones obsolete Number of zones defined in connUnitZoneTable. | column | Integer32 | .1.3.6.1.3.94.1.6.1.18 |
| connUnitModuleId mandatory This is a unique id, persistent between boots,
that can be used to group a set of connUnits
together into a module. The intended use would
be to create a connUnit with a connUnitT… | column | FcGlobalId | .1.3.6.1.3.94.1.6.1.19 |
| connUnitName mandatory A display string containing a name for this
connectivity unit. This object value should be
persistent between boots. | column | OctetString | .1.3.6.1.3.94.1.6.1.20 |
| connUnitInfo mandatory A display string containing information
about this connectivity unit. This object value
should be persistent between boots. | column | RFC1213-MIBDisplayString | .1.3.6.1.3.94.1.6.1.21 |
| connUnitControl mandatory This object is used to control the addressed
connUnit.
NOTE: 'Cold Start' and 'Warm Start'
are as defined in MIB II and are not meant
to be a factory reset.
… | column | Enumeration | .1.3.6.1.3.94.1.6.1.22 |
| connUnitContact mandatory Contact information for this connectivity
unit. Persistent across boots. | column | OctetString | .1.3.6.1.3.94.1.6.1.23 |
| connUnitLocation mandatory Location information for this connectivity
unit.Persistent across boots. | column | OctetString | .1.3.6.1.3.94.1.6.1.24 |
| connUnitEventFilter mandatory This value defines the event severity
that will be logged by this connectivity unit.
All events of severity less than or equal to
connUnitEventFilter are logged in connUnitEventTa… | column | FcEventSeverity | .1.3.6.1.3.94.1.6.1.25 |
| connUnitNumEvents mandatory Number of events currently in the
connUnitEventTable. | column | Integer32 | .1.3.6.1.3.94.1.6.1.26 |
| connUnitMaxEvents mandatory Max number of events that can be defined
in connUnitEventTable. | column | Integer32 | .1.3.6.1.3.94.1.6.1.27 |
| connUnitEventCurrID mandatory The last used event id (connUnitEventIndex). | column | Integer32 | .1.3.6.1.3.94.1.6.1.28 |
| connUnitFabricID mandatory A globally unique value to identify the fabric that this
ConnUnit belongs to, otherwise empty string. This would
typically be equal to the connUnitGlobalID of the
primary switch i… | column | FcGlobalId | .1.3.6.1.3.94.1.6.1.29 |
| connUnitType mandatory The type of this connectivity unit. | column | FcUnitType | .1.3.6.1.3.94.1.6.1.3 |
| connUnitNumLinks mandatory The number of links in the link table. | column | Integer32 | .1.3.6.1.3.94.1.6.1.30 |
| connUnitVendorId mandatory The connectivity unit vendor's name. | column | OctetString | .1.3.6.1.3.94.1.6.1.31 |
| connUnitNumports mandatory Number of physical ports in the connectivity unit
(internal/embedded, external). | column | Integer32 | .1.3.6.1.3.94.1.6.1.4 |
| connUnitState mandatory This object reports the overall state of the
connectivity unit. The meaning of all values
is essentially self-explanatory. Any of these
values may occur with any of the ConnUnit… | column | Enumeration | .1.3.6.1.3.94.1.6.1.5 |
| connUnitStatus mandatory Overall status of the connectivity unit. The goal of this
object is to be the single poll point to check the status
of the connunit. If there is any other component that has
warni… | column | Enumeration | .1.3.6.1.3.94.1.6.1.6 |
| connUnitProduct mandatory The connectivity unit vendor's product
model name. | column | OctetString | .1.3.6.1.3.94.1.6.1.7 |
| connUnitSn mandatory The serial number for this connectivity unit. | column | OctetString | .1.3.6.1.3.94.1.6.1.8 |
| connUnitUpTime mandatory The number of centiseconds since the
last unit initialization. | column | RFC1155-SMITimeTicks | .1.3.6.1.3.94.1.6.1.9 |