te1LoopBackMode

ExaltComProducts · .1.3.6.1.4.1.25651.1.2.3.2.2.4.1.5

Object

column r/w ExaltCommTe1LoopBackModeT
The Loop Back Mode for a T1/E1 interface.
Valid values: disabled(0), ExternalLocal(1), ExternalRemote(2), Internal(3).
All loopback configurations control the loop at the Line Interface integrated circuit,
which is the device wired directly to the front panel ports.
See Web, Configuration, Interface, T1/E1, AIS, Loopback.
To make permanent, write save to commitTe1Settings after change.

Context

MIB
ExaltComProducts
OID
.1.3.6.1.4.1.25651.1.2.3.2.2.4.1.5
Type
column
Access
readwrite
Status
current
Parent
te1Interface
Table
te1Interfaces
Siblings
4

Syntax

ExaltCommTe1LoopBackModeT
Source
ExaltCommTe1LoopBackModeT
Base type
Enumeration

Values & Constraints

Type Values
0lbDisabled
1lbExtLocal
2lbExtRemote
3lbInternal

Related Objects