upsEModuleOutputVAT
EPPC-MIB ·
.1.3.6.1.4.1.935.10.1.1.4.2.1.22
Object
The magnitude of the nominal Volt-Amp rating presented in VA.
Context
- MIB
- EPPC-MIB
- OID
.1.3.6.1.4.1.935.10.1.1.4.2.1.22- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- upsEModulesEntry
- Table
- upsEModulesTable
- Siblings
- 21
Values & Constraints
Type Constraints
range: 0..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsEModulesNum mandatory The number of UPS modules. Serves as index for UPS module table | column | Integer32 | .1.3.6.1.4.1.935.10.1.1.4.2.1.1 |
| upsEModuleWarningCode mandatory The warning code of ups modules.Please refer the warning table of 'QU,XX' for details. | column | OctetString | .1.3.6.1.4.1.935.10.1.1.4.2.1.10 |
| upsEModuleFaultCode mandatory The fault code of ups modules.Please refer command 'QU,XX' for details. | column | OctetString | .1.3.6.1.4.1.935.10.1.1.4.2.1.11 |
| upsEModuleTrapState mandatory the values indicate the unrestored traps.
For example, after AC fail, so the value of upsETrapState should be '1'.
And then the AC restore, the value of upsEModuleTrapState
shou… | column | OctetString | .1.3.6.1.4.1.935.10.1.1.4.2.1.12 |
| upsEModuleConfigOutputVA mandatory The magnitude of the nominal Volt-Amp rating presented in VA. | column | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.4.2.1.13 |
| upsEModuleOutputCurrentS mandatory The measured upsE module output mandatory from the UPS meters in 0.1 A. | column | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.4.2.1.14 |
| upsEModuleOutputCurrentT mandatory The measured upsE module output mandatory from the UPS meters in 0.1 A. | column | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.4.2.1.15 |
| upsEModuleOutputWattS mandatory The measured upsE module output watts from the UPS meters in watts. | column | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.4.2.1.16 |
| upsEModuleOutputWattT mandatory The measured upsE module output watts from the UPS meters in watts. | column | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.4.2.1.17 |
| upsEModuleOutputLoadS mandatory The output load of UPS modules in %. | column | Integer32 | .1.3.6.1.4.1.935.10.1.1.4.2.1.18 |
| upsEModuleOutputLoadT mandatory The output load of UPS modules in %. | column | Integer32 | .1.3.6.1.4.1.935.10.1.1.4.2.1.19 |
| upsEModuleAddress mandatory the address of UPS modules. | column | Integer32 | .1.3.6.1.4.1.935.10.1.1.4.2.1.2 |
| upsEModuleOutputVAR mandatory The magnitude of the nominal Volt-Amp rating presented in VA. | column | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.4.2.1.20 |
| upsEModuleOutputVAS mandatory The magnitude of the nominal Volt-Amp rating presented in VA. | column | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.4.2.1.21 |
| upsEModulePositiveBusVolt mandatory The measured positive upsE module voltage from the UPS meters in 0.1 volts | column | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.4.2.1.3 |
| upsEModuleNegativeBusVolt mandatory The measured nepositive upsE module voltage from the UPS meters in 0.1 volts | column | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.4.2.1.4 |
| upsEModuleTemperature mandatory The measured upsE module temperature from the UPS meters in 0.1 degree. | column | Integer32 | .1.3.6.1.4.1.935.10.1.1.4.2.1.5 |
| upsEModuleWorkingMode mandatory The working mode of UPS modules. | column | Enumeration | .1.3.6.1.4.1.935.10.1.1.4.2.1.6 |
| upsEModuleOutputCurrentR mandatory The measured upsE module output mandatory from the UPS meters in 0.1 A. | column | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.4.2.1.7 |
| upsEModuleOutputWattR mandatory The measured upsE module output watts from the UPS meters in watts. | column | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.4.2.1.8 |
| upsEModuleOutputLoadR mandatory The output load of UPS modules in %. | column | Integer32 | .1.3.6.1.4.1.935.10.1.1.4.2.1.9 |