upsELoadSegment1AutoOnTimer
EPPC-MIB ·
.1.3.6.1.4.1.935.10.1.1.5.4
Object
scalar
mandatory
r/w
Integer32
The load segment is automatically turned on after a selected delay if it has been shutdown due to on battery.
Context
- MIB
- EPPC-MIB
- OID
.1.3.6.1.4.1.935.10.1.1.5.4- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- upsELoadSegment
- Siblings
- 9
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsELoadSegment1OffDelay mandatory Setting this object will shutdown the UPS Load Segment output after the indicated number of seconds, or less.
Setting this object to 0 will cause the shutdown to occur immediatel… | scalar | Integer32 | .1.3.6.1.4.1.935.10.1.1.5.1 |
| upsELoadSegment2State mandatory Load segment output state. | scalar | Enumeration | .1.3.6.1.4.1.935.10.1.1.5.10 |
| upsELoadSegment1OnDelay mandatory Setting this object will start the Load segment output after the indicated number of seconds,
including starting the UPS, if necessary. Setting this object to 0 will cause the s… | scalar | Integer32 | .1.3.6.1.4.1.935.10.1.1.5.2 |
| upsELoadSegment1AutoOffTimer mandatory The load segment turns automatically off after the delay while the unit operates on battery,
but the shutdown is cancelled if the utility return before the delay has expired. | scalar | Integer32 | .1.3.6.1.4.1.935.10.1.1.5.3 |
| upsELoadSegment1State mandatory Load segment output state. | scalar | Enumeration | .1.3.6.1.4.1.935.10.1.1.5.5 |
| upsELoadSegment2OffDelay mandatory Setting this object will shutdown the UPS Load Segment output after the indicated number of seconds, or less.
Setting this object to 0 will cause the shutdown to occur immediatel… | scalar | Integer32 | .1.3.6.1.4.1.935.10.1.1.5.6 |
| upsELoadSegment2OnDelay mandatory Setting this object will start the Load segment output after the indicated number of seconds,
including starting the UPS, if necessary. Setting this object to 0 will cause the s… | scalar | Integer32 | .1.3.6.1.4.1.935.10.1.1.5.7 |
| upsELoadSegment2AutoOffTimer mandatory The load segment turns automatically off after the delay while the unit operates on battery,
but the shutdown is cancelled if the utility return before the delay has expired. | scalar | Integer32 | .1.3.6.1.4.1.935.10.1.1.5.8 |
| upsELoadSegment2AutoOnTimer mandatory The load segment is automatically turned on after a selected delay
if it has been shutdown due to on battery. | scalar | Integer32 | .1.3.6.1.4.1.935.10.1.1.5.9 |