pduUnitConfigIndex
ENLOGIC-PDU-MIB ·
.1.3.6.1.4.1.38446.1.2.2.1.1
Object
column
Integer32
The index of the PDU Unit Config Entry
Context
- MIB
- ENLOGIC-PDU-MIB
- OID
.1.3.6.1.4.1.38446.1.2.2.1.1- Type
- column
- Access
- noaccess
- Status
- current
- Parent
- pduUnitConfigEntry
- Table
- pduUnitConfigTable
- Siblings
- 20
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduUnitConfigUpperWarningThreshold User-defined upper non-critical (warning) unit active power alarm threshold measured in Watts | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.38446.1.2.2.1.10 |
| pduUnitConfigAlarmResetThreshold The hysteresis used for deassertions in Watts | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.38446.1.2.2.1.11 |
| pduUnitConfigAlarmStateChangeDelay The delay measured in samples before a state is asserted. If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.38446.1.2.2.1.12 |
| pduUnitConfigEnabledThresholds A bit string indicating which alarm thresholds are enabled | column | Bits | .1.3.6.1.4.1.38446.1.2.2.1.13 |
| pduUnitConfigPeakPowerReset Setting this OID to reset (2) will cause the existing peak power value
to be replaced by the current load power value. Getting this OID will
do nothing and return the noOperatio… | column | Enumeration | .1.3.6.1.4.1.38446.1.2.2.1.14 |
| pduUnitConfigEnergyReset Setting this OID to reset (2) will cause the device energy meter value
to be reset to zero. Getting this OID in models that support this
feature will do nothing and return the n… | column | Enumeration | .1.3.6.1.4.1.38446.1.2.2.1.15 |
| pduUnitConfigOutletPeakPowerReset Setting this OID to reset (2) will cause the outlet peak power meter value
to be reset to zero. Getting this OID in models that support this
feature will do nothing and return t… | column | Enumeration | .1.3.6.1.4.1.38446.1.2.2.1.16 |
| pduUnitConfigOutletEnergyReset Setting this OID to reset (2) will cause the outlet energy meter value
to be reset to zero. Getting this OID in models that support this
feature will do nothing and return the n… | column | Enumeration | .1.3.6.1.4.1.38446.1.2.2.1.17 |
| pduUnitConfigUsb Setting this OID to off(0) will disable the USB port. Setting this OID to on(1) will enable the USB port. | column | Enumeration | .1.3.6.1.4.1.38446.1.2.2.1.18 |
| pduUnitConfigSsh Setting this OID to off(0) will disable the SSH connection. Setting this OID to on(1) will enable the SSH connection. | column | Enumeration | .1.3.6.1.4.1.38446.1.2.2.1.19 |
| pduUnitConfigName A user-defined string identifying the PDU | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.38446.1.2.2.1.2 |
| pduUnitConfigResetNetworkManagementCard Getting this OID will return noOperation(0). Setting this OID to reset(1) will reset NMC. | column | Enumeration | .1.3.6.1.4.1.38446.1.2.2.1.20 |
| pduUnitConfigDaisyChainState Setting this OID to daisychain(0) will enable daisychain mode. | column | Enumeration | .1.3.6.1.4.1.38446.1.2.2.1.21 |
| pduUnitConfigLocation A user-defined string identifying the location of the PDU | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.38446.1.2.2.1.3 |
| pduUnitConfigDisplayOrientation Indicates the intended physical orientation of the oLED display
displayNormal (1) indicates normal orientation.
displayReverse (2) indicates upside down orientation | column | Enumeration | .1.3.6.1.4.1.38446.1.2.2.1.4 |
| pduUnitConfigColdstartDelay The amount of time, specified in seconds, between when power
is provided to the PDU and when the PDU start providing basic master
power to the outlets | column | Unsigned32 | .1.3.6.1.4.1.38446.1.2.2.1.5 |
| pduUnitConfigGlobalOutletStateOnStartup The outlet state on device startup; applies to all outlets
unless overridden at the outlet level | column | Enumeration | .1.3.6.1.4.1.38446.1.2.2.1.6 |
| pduUnitConfigLowerCriticalThreshold User-defined lower critical unit active power alarm threshold measured in Watts | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.38446.1.2.2.1.7 |
| pduUnitConfigLowerWarningThreshold User-defined lower non-critical (warning) unit active power alarm threshold measured in Watts | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.38446.1.2.2.1.8 |
| pduUnitConfigUpperCriticalThreshold User-defined upper critical unit active power alarm threshold measured in Watts | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.38446.1.2.2.1.9 |