reset

ELECTROLINE-DHT-TEST-MIB · .1.3.6.1.4.1.5802.1.3.1.2.4.1.3.3

Object

scalar r/w Integer32
The Read command returns the last DHT reset cause as follows:
0: Unknown reset cause (= error while reading).
1: Power On reset
2: Hard reset
3: Soft reset
4: Atmel Watchdog reset
5: Shutdown reset
          
Writing a value to this MIB causes the DHT to execute a reset of the
requested type (Only Hard, Soft and ShutDown are allowed).
          
The shutdown reset uses the parameters wakeUpVoltage and wakeUpPortId
which must be set before setting this MIB to 5.

Context

MIB
ELECTROLINE-DHT-TEST-MIB
OID
.1.3.6.1.4.1.5802.1.3.1.2.4.1.3.3
Type
scalar
Access
readwrite
Status
current
Parent
dhtMicroControllers
Siblings
4

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-5

Related Objects

Sibling Objects