ELECTROLINE-DHT-TEST-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
13
.1.3.6.1.4.1.5802.1.3.1.2.4.1.1.1 · 1 row entry · 3 columns
Provide Read access to Analog Ports
currentAnalogValueEntry entry .1.3.6.1.4.1.5802.1.3.1.2.4.1.1.1.1
Analog port index and value
Indexes
analogPortId
Column Syntax OID
analogPortId
Index into analog value table, all analog ports are enumerated
together starting at zero.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5802.1.3.1.2.4.1.1.1.1.1
analogValue
Returns the current value of the analog port. When calibrated, the displayed value
is in the unit used for the calibration settings.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5802.1.3.1.2.4.1.1.1.1.2
analogPortIdDesc
Returns the name of the current PortId
OctetString .1.3.6.1.4.1.5802.1.3.1.2.4.1.1.1.1.3
.1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6 · 1 row entry · 4 columns
Provides Read access to Analog Calibration Table.
currentCalibrationValueEntry entry .1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6.1
Displays the stored analog calibration table content.
Indexes
analogCalibrationPortId
Column Syntax OID
analogCalibrationPortId
Index into analog value table. Each analog port has an entry in the calibration table.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6.1.1
rawValue
Returns a rawValue that corresponds to the calibrated value.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6.1.2
calibratedValue
Returns the real display value at calibration time.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6.1.3
calibratedPortIdDesc
Returns the name of the current PortId.
OctetString .1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6.1.4
.1.3.6.1.4.1.5802.1.3.1.2.4.1.2.1 · 1 row entry · 3 columns
Provides Read access to Digital Status (Input)Ports.
currentDigitalStatusEntry entry .1.3.6.1.4.1.5802.1.3.1.2.4.1.2.1.1
Digital Status (Input) port index and value.
Indexes
statusPortId
Column Syntax OID
statusPortId
Index into digital Status value table. All digital ports
are enumerated together starting at zero.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5802.1.3.1.2.4.1.2.1.1.1
statusValue
Current value of the port
0: Unknown state (read error)
1: OFF (Inactive)
2: ON (Active)
Note that inverse polarity is taken into account.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5802.1.3.1.2.4.1.2.1.1.2
statusPortIdDesc
Returns the name of the current PortId.
OctetString .1.3.6.1.4.1.5802.1.3.1.2.4.1.2.1.1.3
.1.3.6.1.4.1.5802.1.3.1.2.4.1.2.2 · 1 row entry · 3 columns
Provides Read/Write access to Digital Control (output) Ports.
currentDigitalControlEntry entry .1.3.6.1.4.1.5802.1.3.1.2.4.1.2.2.1
Digital Control (output) port index and value.
Indexes
controlPortId
Column Syntax OID
controlPortId
Index into digital Control value table. All digital ports
are enumerated together starting at zero.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5802.1.3.1.2.4.1.2.2.1.1
controlValue
Current value of the digital port
0: Unknown state (Read Error)
1: OFF (Inactive)
2: ON (Active)

Note that inverse polarity is taken into account.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5802.1.3.1.2.4.1.2.2.1.2
controlPortIdDesc
Gives the name of the current PortId
OctetString .1.3.6.1.4.1.5802.1.3.1.2.4.1.2.2.1.3