analogCalibrationSetDefault
ELECTROLINE-DHT-TEST-MIB ·
.1.3.6.1.4.1.5802.1.3.1.2.4.1.1.5
Object
scalar
r/w
Integer32
Set this MIB to 1 to reset all the calibration values to the factory default.
Context
- MIB
- ELECTROLINE-DHT-TEST-MIB
- OID
.1.3.6.1.4.1.5802.1.3.1.2.4.1.1.5- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- dhtAnalogPorts
- Siblings
- 5
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-1
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| currentAnalogValueTable Provide Read access to Analog Ports | table | - | .1.3.6.1.4.1.5802.1.3.1.2.4.1.1.1 |
| analogCalibrationValue Calibration value for portID | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.5802.1.3.1.2.4.1.1.2 |
| analogPortToCalibrate portID to calibrate: Writes analogCalibrationValue first then sets associated portID.
The analogCalibrationCommit must be set after all ports are calibrated to store the
values … | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.5802.1.3.1.2.4.1.1.3 |
| analogCalibrationCommit Must be set to 1 after all ports are calibrated in order to store the values in non-volatile
memory. The Read command always returns the value 0. | scalar | Integer32 | .1.3.6.1.4.1.5802.1.3.1.2.4.1.1.4 |
| currentCalibrationValueTable Provides Read access to Analog Calibration Table. | table | - | .1.3.6.1.4.1.5802.1.3.1.2.4.1.1.6 |