enetTestQosControl

ELECTROLINE-DHT-ENET-MIB · .1.3.6.1.4.1.5802.1.3.1.2.5.1.12.1.3.1.1.1.14

Object

column r/w Enumeration
This parameter tells the DHT is a specific service flow must be used
for the test.
              
none(1): Means that the test will run in a best effort mode.
              
preestablished(2): tells the DHT that a high priority service flow has
					been established by an external mean.
              
dsa(3):  	Request that the DHT takes care of establishing a high 
			priority service flow usign Dynamic Service Add messages to
			the CMTS.

Context

MIB
ELECTROLINE-DHT-ENET-MIB
OID
.1.3.6.1.4.1.5802.1.3.1.2.5.1.12.1.3.1.1.1.14
Type
column
Access
readwrite
Status
current
Parent
enetTestControlEntry
Table
enetTestControlTable
Siblings
18

Syntax

Enumeration

Values & Constraints

Enumerated Values
1none
2preestablished
3dsa

Related Objects