psSetting
EES-POWER-MIB ·
.1.3.6.1.4.1.6302.2.1.2.26
Object
node
No description available.
Context
- MIB
- EES-POWER-MIB
- OID
.1.3.6.1.4.1.6302.2.1.2.26- Type
- node
- Parent
- system
- Siblings
- 26
- Children
- 15
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| systemStatus Status of the complete plant (highest alarm). One of
(1) unknown - status has not yet been defined
(2) normal - there are no activated alarms
(3) warning - OA, lowest level of 'ab… | scalar | Status | .1.3.6.1.4.1.6302.2.1.2.1 |
| psSMNumber | node | - | .1.3.6.1.4.1.6302.2.1.2.10 |
| psRectifier | node | - | .1.3.6.1.4.1.6302.2.1.2.11 |
| psDistribution | node | - | .1.3.6.1.4.1.6302.2.1.2.12 |
| psConverter | node | - | .1.3.6.1.4.1.6302.2.1.2.13 |
| psControl | node | - | .1.3.6.1.4.1.6302.2.1.2.14 |
| psEquipmentSignalTable Table of indexed equipment signal values. | table | - | .1.3.6.1.4.1.6302.2.1.2.15 |
| ambientTemperature AmbientTemperature.
The integer 2147483647 represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.16 |
| autoManualMode Auto/Manual Mode of system.
The integer 2147483647 represents invalid value. | scalar | Enumeration | .1.3.6.1.4.1.6302.2.1.2.17 |
| psLVDVoltage | node | - | .1.3.6.1.4.1.6302.2.1.2.18 |
| psDCLowVoltage | node | - | .1.3.6.1.4.1.6302.2.1.2.19 |
| systemVoltage System voltage, stored as mV, including positive or negative
sign. The integer 2147483647 represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.2 |
| acLowVoltage | node | - | .1.3.6.1.4.1.6302.2.1.2.20 |
| psSMDUHCurrent | node | - | .1.3.6.1.4.1.6302.2.1.2.21 |
| psSMDUHPower | node | - | .1.3.6.1.4.1.6302.2.1.2.22 |
| psSMDUHEnergy | node | - | .1.3.6.1.4.1.6302.2.1.2.23 |
| psSMDU | node | - | .1.3.6.1.4.1.6302.2.1.2.24 |
| psSolar | node | - | .1.3.6.1.4.1.6302.2.1.2.25 |
| psCabinet | node | - | .1.3.6.1.4.1.6302.2.1.2.27 |
| systemCurrent System current, stored as mA, including positive or negative
sign. The integer 2147483647 represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.3 |
| systemUsedCapacity Used capacity, stored as % of the total capacity.
The integer 2147483647 represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.4 |
| psBattery | node | - | .1.3.6.1.4.1.6302.2.1.2.5 |
| psInput | node | - | .1.3.6.1.4.1.6302.2.1.2.6 |
| psTemperature | node | - | .1.3.6.1.4.1.6302.2.1.2.7 |
| psStatusCommunication The status of communication with the Power System. interrupt(3) indicates
some errors occurred between Power System and agent. | scalar | Enumeration | .1.3.6.1.4.1.6302.2.1.2.8 |
| psStatusBatteryMode The status of battery modes,
FloatCharging(2),
ShortTest(3),
BoostChargingForTest(4),
ManualTesting(5),
PlanTesting(6),
ACFailTesting(7),
ACFail(8),
ManualBoostCharging(9),
AutoB… | scalar | Enumeration | .1.3.6.1.4.1.6302.2.1.2.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| settingSolarFloatVoltage Solar Float voltage stored as mV | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.1 |
| settingGeneratorPowerLimitEnable Diesel Generator Power Limit Enable,
Disabled(0),
Active(1) | scalar | Enumeration | .1.3.6.1.4.1.6302.2.1.2.26.10 |
| settingGeneratorPowerLimitPoint Diesel Generator Power Limit point in percent * 1000. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.11 |
| settingGeneratorStartVoltage Diesel Generator Start voltage stored as mV | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.12 |
| settingGeneratorStopVoltage Diesel Generator Stop voltage stored as mV | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.13 |
| settingHybridMode Solar mode,
Disabled(0),
RECT-SOLAR(1),
Solar(2) | scalar | Enumeration | .1.3.6.1.4.1.6302.2.1.2.26.14 |
| settingGeneratorRelay Diesel Generator Relay,
None(0),
Relay Output 1(1),
Relay Output 2(2),
Relay Output 3(3),
Relay Output 4(4),
Relay Output 5(5),
Relay Output 6(6),
Relay Output 7(7),
Relay Output … | scalar | Enumeration | .1.3.6.1.4.1.6302.2.1.2.26.15 |
| settingSolarEQChargeVoltage Solar Equalize voltage stored as mV | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.2 |
| settingRectifierFloatVoltage Rectifier Float voltage stored as mV | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.3 |
| settingRectifierEQChargeVoltage Rectifier Equalize voltage stored as mV | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.4 |
| settingRectifierWalkInEnable Rectifier walk-in Enable,
Disabled(0),
Active(1) | scalar | Enumeration | .1.3.6.1.4.1.6302.2.1.2.26.5 |
| settingRectifierWalkInTime Rectifier walk-in time in seconds. | scalar | Integer32 | .1.3.6.1.4.1.6302.2.1.2.26.6 |
| settingRectifierCurrentLimitEnable Rectifier Current Limit Enable,
Disabled(0),
Active(1) | scalar | Enumeration | .1.3.6.1.4.1.6302.2.1.2.26.7 |
| settingRectifierCurrentLimit Rectifier current limit stored as mA | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.8 |
| settingRectifierInputCurrentLimit Rectifier input current limit stored as mA | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.9 |