EES-POWER-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
13
Rows
13
Columns
126
.1.3.6.1.4.1.6302.2.1.2.5.5 · 1 row entry · 6 columns
Battery Table.
psBatteryEntry entry .1.3.6.1.4.1.6302.2.1.2.5.5.1
Battery Measurement Table Entry.
Indexes
psBatteryIndex
Column Syntax OID
psBatteryIndex
Automatically generated index object.
Integer32
Constraints:
range: 1-16777215
.1.3.6.1.4.1.6302.2.1.2.5.5.1.1
psBatteryCurrent
Battery current in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.5.5.1.2
psBatteryName
Battery shunt name.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.5.5.1.3
psBatteryRatedCapacity
Battery reted capacity.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.5.5.1.4
psBatteryCapacity
Battery capacity in Ah.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.5.5.1.5
psBatteryCapacityPercent
Battery capacity in percent.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.5.5.1.6
.1.3.6.1.4.1.6302.2.1.2.7.3 · 1 row entry · 5 columns
Temperature Measurement Table.
psTemperatureEntry entry .1.3.6.1.4.1.6302.2.1.2.7.3.1
Temperature Measurement Table Entry.
Indexes
psTemperatureIndex
Column Syntax OID
psTemperatureIndex
Temperature Probe Number
Integer32
Constraints:
range: 1-71
.1.3.6.1.4.1.6302.2.1.2.7.3.1.1
psTemperatureMeasurement
Temperature Value In 0.001 Celsius Degree.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.7.3.1.2
psTemperatureName
Configured Temperature Probe Name.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.7.3.1.3
psTemperatureType
Temperature Probe Type
Enumeration
Enumerated Values:
0none
1ambient
2battery
.1.3.6.1.4.1.6302.2.1.2.7.3.1.4
psTemperatureAlarmStatus
Temperature Probe Alarm Status
Enumeration
Enumerated Values:
0high
1low
2fail
3none
.1.3.6.1.4.1.6302.2.1.2.7.3.1.5
.1.3.6.1.4.1.6302.2.1.2.11.4 · 1 row entry · 9 columns
Table holding information about indivual rectifiers.
psRectifierEntry entry .1.3.6.1.4.1.6302.2.1.2.11.4.1
An entry (conceptual row) in the rectifierInfoTable.
Indexes
psRectifierIndex
Column Syntax OID
psRectifierIndex
Automatically generated index object.
Integer32
Constraints:
range: 1-16777215
.1.3.6.1.4.1.6302.2.1.2.11.4.1.1
psRectifierProductNumber
Rectifier Product Number.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.11.4.1.2
psRectifierHWVersion
Rectifier Hardware Revision.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.11.4.1.3
psRectifierSWVersion
Rectifier Software Revision.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.11.4.1.4
psRectifierSerialNumber
Rectifier Serial Number.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.11.4.1.5
psRectifierCurrent
Rectifier Current.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.11.4.1.6
psRectifierIdent
Rectifier physical location identifier.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.11.4.1.7
psRectifierFail
The type of alarm change. One of
(1) activated
(2) deactivated
StatusChange
Textual Convention: StatusChange Enumeration
Type Values:
1activated
2deactivated
.1.3.6.1.4.1.6302.2.1.2.11.4.1.8
psRectifierTemperature
Rectifier Temperature.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.11.4.1.9
.1.3.6.1.4.1.6302.2.1.2.12.2 · 1 row entry · 3 columns
Distribution Table.
psDistributionLoadEntry entry .1.3.6.1.4.1.6302.2.1.2.12.2.1
Distribution Measurement Table Entry.
Indexes
psDistributionLoadIndex
Column Syntax OID
psDistributionLoadIndex
Automatically generated index object.
Integer32
Constraints:
range: 1-268386303
.1.3.6.1.4.1.6302.2.1.2.12.2.1.1
psDistributionLoadCurrent
Distribution current in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.12.2.1.2
psDistributionLoadName
Distribution name.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.12.2.1.3
.1.3.6.1.4.1.6302.2.1.2.12.3 · 1 row entry · 3 columns
Distribution Table.
psDistributionGeneralEntry entry .1.3.6.1.4.1.6302.2.1.2.12.3.1
Distribution Measurement Table Entry.
Indexes
psDistributionGeneralIndex
Column Syntax OID
psDistributionGeneralIndex
Automatically generated index object.
Integer32
Constraints:
range: 1-268386303
.1.3.6.1.4.1.6302.2.1.2.12.3.1.1
psDistributionGeneralCurrent
Distribution current in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.12.3.1.2
psDistributionGeneralName
Distribution name.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.12.3.1.3
.1.3.6.1.4.1.6302.2.1.2.13.6 · 1 row entry · 8 columns
Table holding information about indivual converters.
psConverterEntry entry .1.3.6.1.4.1.6302.2.1.2.13.6.1
An entry (conceptual row) in the ConverterInfoTable.
Indexes
psConverterIndex
Column Syntax OID
psConverterIndex
Automatically generated index object.
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.6302.2.1.2.13.6.1.1
psConverterProductNumber
Converter Product Number.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.13.6.1.2
psConverterHWVersion
Converter Hardware Revision.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.13.6.1.3
psConverterSWVersion
Converter Software Revision.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.13.6.1.4
psConverterSerialNumber
Converter Serial Number.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.13.6.1.5
psConverterCurrent
Converter Current.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.13.6.1.6
psConverterIdent
Converter physical location identifier.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.2.13.6.1.7
psConverterFail
The type of alarm change. One of
(1) activated
(2) deactivated
StatusChange
Textual Convention: StatusChange Enumeration
Type Values:
1activated
2deactivated
.1.3.6.1.4.1.6302.2.1.2.13.6.1.8
.1.3.6.1.4.1.6302.2.1.2.15 · 1 row entry · 2 columns
Table of indexed equipment signal values.
equipmentSignalTableEntry entry .1.3.6.1.4.1.6302.2.1.2.15.1
An entry (conceptual row) in the psEquipment Signal Table.
Indexes
psEquipmentSignalTableEntryIndex
Column Syntax OID
psEquipmentSignalTableEntryIndex
The unique sequence number of this equipment signal.
Integer32
Constraints:
range: 1-268386303
.1.3.6.1.4.1.6302.2.1.2.15.1.1
psEquipmentSignalValue
Indexed equipment signal value.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.15.1.2
.1.3.6.1.4.1.6302.2.1.2.21.10 · 1 row entry · 21 columns
Table holding information about SMDUH currents.
psSMDUHCurrentEntry entry .1.3.6.1.4.1.6302.2.1.2.21.10.1
An entry (conceptual row) in the SMDUHTable.
Indexes
psSMDUHCurrentIndex
Column Syntax OID
psSMDUHCurrentIndex
Automatically generated index object.
Integer32
Constraints:
range: 1-64
.1.3.6.1.4.1.6302.2.1.2.21.10.1.1
psSMDUHCurrent1
SMDUH Current 1 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.2
psSMDUHCurrent2
SMDUH Current 2 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.3
psSMDUHCurrent3
SMDUH Current 3 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.4
psSMDUHCurrent4
SMDUH Current 4 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.5
psSMDUHCurrent5
SMDUH Current 5 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.6
psSMDUHCurrent6
SMDUH Current 6 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.7
psSMDUHCurrent7
SMDUH Current 7 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.8
psSMDUHCurrent8
SMDUH Current 8 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.9
psSMDUHCurrent9
SMDUH Current 9 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.10
psSMDUHCurrent10
SMDUH Current 10 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.11
psSMDUHCurrent11
SMDUH Current 11 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.12
psSMDUHCurrent12
SMDUH Current 12 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.13
psSMDUHCurrent13
SMDUH Current 13 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.14
psSMDUHCurrent14
SMDUH Current 14 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.15
psSMDUHCurrent15
SMDUH Current 15 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.16
psSMDUHCurrent16
SMDUH Current 16 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.17
psSMDUHCurrent17
SMDUH Current 17 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.18
psSMDUHCurrent18
SMDUH Current 18 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.19
psSMDUHCurrent19
SMDUH Current 19 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.20
psSMDUHCurrent20
SMDUH Current 20 in mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.21.10.1.21
.1.3.6.1.4.1.6302.2.1.2.22.1 · 1 row entry · 21 columns
Table holding information about SMDUH power.
psSMDUHPowerEntry entry .1.3.6.1.4.1.6302.2.1.2.22.1.1
An entry (conceptual row) in the SMDUHPowerTable.
Indexes
psSMDUHPowerIndex
Column Syntax OID
psSMDUHPowerIndex
Automatically generated index object.
Integer32
Constraints:
range: 1-64
.1.3.6.1.4.1.6302.2.1.2.22.1.1.1
psSMDUHPower1
SMDUH Power 1 in thousandths of kW.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.2
psSMDUHPower2
SMDUH Power 2.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.3
psSMDUHPower3
SMDUH Power 3.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.4
psSMDUHPower4
SMDUH Power 4.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.5
psSMDUHPower5
SMDUH Power 5.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.6
psSMDUHPower6
SMDUH Power 6.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.7
psSMDUHPower7
SMDUH Power 7.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.8
psSMDUHPower8
SMDUH Power 8.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.9
psSMDUHPower9
SMDUH Power 9.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.10
psSMDUHPower10
SMDUH Power 10.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.11
psSMDUHPower11
SMDUH Power 11.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.12
psSMDUHPower12
SMDUH Power 12.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.13
psSMDUHPower13
SMDUH Power 13.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.14
psSMDUHPower14
SMDUH Power 14.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.15
psSMDUHPower15
SMDUH Power 15.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.16
psSMDUHPower16
SMDUH Power 16.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.17
psSMDUHPower17
SMDUH Power 17.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.18
psSMDUHPower18
SMDUH Power 18.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.19
psSMDUHPower19
SMDUH Power 19.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.20
psSMDUHPower20
SMDUH Power 20.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.22.1.1.21
.1.3.6.1.4.1.6302.2.1.2.23.1 · 1 row entry · 21 columns
Table holding information about SMDUH energy counters.
psSMDUHEnergyEntry entry .1.3.6.1.4.1.6302.2.1.2.23.1.1
An entry (conceptual row) in the SMDUHEnergyTable.
Indexes
psSMDUHEnergyIndex
Column Syntax OID
psSMDUHEnergyIndex
Automatically generated index object.
Integer32
Constraints:
range: 1-64
.1.3.6.1.4.1.6302.2.1.2.23.1.1.1
psSMDUHTotalEnergy1
SMDUH Total Energy 1.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.2
psSMDUHTotalEnergy2
SMDUH Total Energy 2.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.3
psSMDUHTotalEnergy3
SMDUH Total Energy 3.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.4
psSMDUHTotalEnergy4
SMDUH Total Energy 4.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.5
psSMDUHTotalEnergy5
SMDUH Total Energy 5.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.6
psSMDUHTotalEnergy6
SMDUH Total Energy 6.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.7
psSMDUHTotalEnergy7
SMDUH Total Energy 7.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.8
psSMDUHTotalEnergy8
SMDUH Total Energy 8.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.9
psSMDUHTotalEnergy9
SMDUH Total Energy 9.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.10
psSMDUHTotalEnergy10
SMDUH Total Energy 10.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.11
psSMDUHTotalEnergy11
SMDUH Total Energy 11.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.12
psSMDUHTotalEnergy12
SMDUH Total Energy 12.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.13
psSMDUHTotalEnergy13
SMDUH Total Energy 13.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.14
psSMDUHTotalEnergy14
SMDUH Total Energy 14.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.15
psSMDUHTotalEnergy15
SMDUH Total Energy 15.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.16
psSMDUHTotalEnergy16
SMDUH Total Energy 16.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.17
psSMDUHTotalEnergy17
SMDUH Total Energy 17.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.18
psSMDUHTotalEnergy18
SMDUH Total Energy 18.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.19
psSMDUHTotalEnergy19
SMDUH Total Energy 19.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.20
psSMDUHTotalEnergy20
SMDUH Total Energy 20.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.23.1.1.21
.1.3.6.1.4.1.6302.2.1.2.24.1 · 1 row entry · 16 columns
Table holding information about SMDU.
psSMDUEntry entry .1.3.6.1.4.1.6302.2.1.2.24.1.1
An entry (conceptual row) in the SMDU Table.
Indexes
psSMDUIndex
Column Syntax OID
psSMDUIndex
Automatically generated index object.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.6302.2.1.2.24.1.1.1
psSMDULoad1Power
SMDU Load1 Power in thousandths of kW
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.2
psSMDULoad2Power
SMDU Load2 Power in thousandths of kW
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.3
psSMDULoad3Power
SMDU Load3 Power in thousandths of kW
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.4
psSMDULoad4Power
SMDU Load4 Power in thousandths of kW
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.5
psSMDULoad5Power
SMDU Load5 Power in thousandths of kW
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.6
psSMDUShunt1FullScaleCurrent
SMDU Shunt1 Full Scale Current in mA.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.7
psSMDUShunt1FullScaleVoltage
SMDU Shunt1 Full Scale Voltage in thousandths of mV.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.8
psSMDUShunt2FullScaleCurrent
SMDU Shunt2 Full Scale Current in mA.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.9
psSMDUShunt2FullScaleVoltage
SMDU Shunt2 Full Scale Voltage in thousandths of mV.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.10
psSMDUShunt3FullScaleCurrent
SMDU Shunt3 Full Scale Current in mA.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.11
psSMDUShunt3FullScaleVoltage
SMDU Shunt3 Full Scale Voltage in thousandths of mV.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.12
psSMDUShunt4FullScaleCurrent
SMDU Shunt4 Full Scale Current in mA.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.13
psSMDUShunt4FullScaleVoltage
SMDU Shunt4 Full Scale Voltage in thousandths of mV.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.14
psSMDUShunt5FullScaleCurrent
SMDU Shunt5 Full Scale Current in mA.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.15
psSMDUShunt5FullScaleVoltage
SMDU Shunt5 Full Scale Voltage in thousandths of mV.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.24.1.1.16
.1.3.6.1.4.1.6302.2.1.2.27.1 · 1 row entry · 5 columns
Table holding information about Cabinet.
psCabinetEntry entry .1.3.6.1.4.1.6302.2.1.2.27.1.1
An entry (conceptual row) in the Cabinet Table.
Indexes
psCabinetIndex
Column Syntax OID
psCabinetIndex
Automatically generated index object.
Integer32
Constraints:
range: 1-20
.1.3.6.1.4.1.6302.2.1.2.27.1.1.1
psCabinetTotalCurrent
Cabinet Total Current in mA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.27.1.1.2
psCabinetTotalPower
Cabinet Total Power in thousandths of W
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.27.1.1.3
psCabinetTotalEnergy
Cabinet Total Energy in thousandths of KWh
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.2.27.1.1.4
psCabinetAlarmStatus
Cabinet Alarm Status
Enumeration
Enumerated Values:
0notAlarmed
1alarmLevel1
2alarmLevel2
.1.3.6.1.4.1.6302.2.1.2.27.1.1.5
.1.3.6.1.4.1.6302.2.1.4 · 1 row entry · 6 columns
Table holding information about the currently active alarms.
activeAlarmEntry entry .1.3.6.1.4.1.6302.2.1.4.1
An entry (conceptual row) in the alarmTrapTable.
Indexes
alarmIndex
Column Syntax OID
alarmIndex
The unique sequence number of this alarm trap.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6302.2.1.4.1.1
alarmTime
Date and time when event occured (local time), including
timezone if supported by controller.
SNMPv2-TCDateAndTime
Textual Convention: SNMPv2-TCDateAndTime OctetString
Type Constraints:
range: 8
range: 11
.1.3.6.1.4.1.6302.2.1.4.1.2
alarmStatusChange
The type of alarm change. One of
(1) activated
(2) deactivated
StatusChange
Textual Convention: StatusChange Enumeration
Type Values:
1activated
2deactivated
.1.3.6.1.4.1.6302.2.1.4.1.3
alarmSeverity
The severity of the alarm. One of
(3) warning - OA, lowest level of alarm severity
(4) minor - A3
(5) major - MA
(6) critical - CA, highest level of alarm severity
Status
Textual Convention: Status Enumeration
Type Values:
1unknown
2normal
3warning
4minor
5major
6critical
7unmanaged
8restricted
9testing
10disabled
.1.3.6.1.4.1.6302.2.1.4.1.4
alarmDescription
Free-text description of alarm.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.6302.2.1.4.1.5
alarmType
Alarm type, i.e. an integer specifying the type of alarm.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6302.2.1.4.1.6