inputCurrentEntry
EATON-EPDU-MIB ·
.1.3.6.1.4.1.534.6.6.7.3.3.1
Object
row
An entry for a particular input current measurement.
Context
- MIB
- EATON-EPDU-MIB
- OID
.1.3.6.1.4.1.534.6.6.7.3.3.1- Type
- row
- Status
- current
- Parent
- inputCurrentTable
- Table
- inputCurrentTable
- Children
- 12
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| inputCurrentIndex A unique value for each input current measurement. Its value ranges
from 1 to inputCurrentCount. | column | Integer32 | .1.3.6.1.4.1.534.6.6.7.3.3.1.1 |
| inputCurrentCrestFactor Current crest factor. Units are in milli, for example a crest factor of
1.414 will be returned as 1414. A negative value indicates
that this object is not available. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.534.6.6.7.3.3.1.10 |
| inputCurrentPercentLoad Current percent load, based on the rated current capacity. Units are
percentage, for example 80% will be returned as 80. A negative
value indicates that this object is not avail… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.534.6.6.7.3.3.1.11 |
| inputPhaseDesignator Alphanumeric physical name for the input. | column | OctetString | .1.3.6.1.4.1.534.6.6.7.3.3.1.12 |
| inputCurrentMeasType Which input wire is being measured in this table row - single phase, neutral, phase 1,
phase 2, or phase 3. | column | Enumeration | .1.3.6.1.4.1.534.6.6.7.3.3.1.2 |
| inputCurrentCapacity Rated current capacity of the input. A negative value indicates that
the hardware current capacity is unknown. Units are milliamps. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.534.6.6.7.3.3.1.3 |
| inputCurrent An input current measurement value. Units are milliamps. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.534.6.6.7.3.3.1.4 |
| inputCurrentThStatus Status of the measured input current relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.534.6.6.7.3.3.1.5 |
| inputCurrentThLowerWarning Lower warning threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.534.6.6.7.3.3.1.6 |
| inputCurrentThLowerCritical Lower critical threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.534.6.6.7.3.3.1.7 |
| inputCurrentThUpperWarning Upper warning threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.534.6.6.7.3.3.1.8 |
| inputCurrentThUpperCritical Upper critical threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.534.6.6.7.3.3.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| strappingIndex For units that support 'strapping' functionality, this will be a unique
value for each unit. If units do not support 'strapping', this will
always be '0'. | column | Integer32 | .1.3.6.1.4.1.534.6.6.7.1.2.1.1 |
| inputIndex A unique value for each input. Its value ranges from 1 to inputCount. | column | Integer32 | .1.3.6.1.4.1.534.6.6.7.3.1.1.1 |
| inputCurrentIndex A unique value for each input current measurement. Its value ranges