dupsPMStsPFCInnerCommFail
DeltaUPSv5-MIB ·
.1.3.6.1.4.1.2254.2.5.10.6.1.25
Object
column
mandatory
Enumeration
Indicates the power module PFC inner communication fail.
Context
- MIB
- DeltaUPSv5-MIB
- OID
.1.3.6.1.4.1.2254.2.5.10.6.1.25- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- dupsPMEntry
- Table
- dupsPMTable
- Siblings
- 45
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | alarm |
2 | normal |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dupsPMID mandatory The power module identifier. | column | Integer32 | .1.3.6.1.4.1.2254.2.5.10.6.1.1 |
| dupsPMStsNotExist mandatory Indicates the power module is existed or not? | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.10 |
| dupsPMStsOff mandatory Indicates the power module is on or off? | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.11 |
| dupsPMStsRepair mandatory Indicates the power module is in repair mode or not? | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.12 |
| dupsPMStsFaultShutdown mandatory Indicates the power module status of fault shutdown. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.13 |
| dupsPMStsPFCFuseFail mandatory Indicates the power module PFC fuse open or close? | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.14 |
| dupsPMStsPFCOverTempWarning mandatory Indicates the power module PFC over temperature warning. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.15 |
| dupsPMStsPFCOverTempShutdown mandatory Indicates the power module PFC over temperature shutdown. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.16 |
| dupsPMStsPFCOverVoltWarning mandatory Indicates the power module PFC over voltage warning. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.17 |
| dupsPMStsPFCOverVoltShutdown mandatory Indicates the power module PFC over voltage shutdown. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.18 |
| dupsPMStsPFCUnderVoltWarning mandatory Indicates the power module PFC under voltage warning. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.19 |
| dupsPMPFCTemp mandatory The power module PFC temperature. | column | 1 Degree Celsius Integer32 | .1.3.6.1.4.1.2254.2.5.10.6.1.2 |
| dupsPMStsPFCUnderVoltShutdown mandatory Indicates the power module PFC under voltage shutdown. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.20 |
| dupsPMStsPFCGeneralFault mandatory Indicates the power module PFC genreal fault. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.21 |
| dupsPMStsPFCFanFail mandatory Indicates the power module PFC fan fail. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.22 |
| dupsPMStsPFCCurrentLimit mandatory Indicates the power module PFC output current limit. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.23 |
| dupsPMStsPFCOff mandatory Indicates the power module PFC off. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.24 |
| dupsPMStsPFCNotCalibrated mandatory Indicates the power module PFC is not calibrated. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.26 |
| dupsPMStsINVFuseFail mandatory Indicates the power module Inverter fuse open or close? | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.27 |
| dupsPMStsINVOverTempWarning mandatory Indicates the power module Inverter over temperature warning. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.28 |
| dupsPMStsINVOverTempShutdown mandatory Indicates the power module Inverter over temperature shutdown. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.29 |
| dupsPMINVTemp mandatory The power module inverter temperature. | column | 1 Degree Celsius Integer32 | .1.3.6.1.4.1.2254.2.5.10.6.1.3 |
| dupsPMStsINVFanFail mandatory Indicates the power module Inverter fan fail. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.30 |
| dupsPMStsINVShortCircuit mandatory Indicates the power module Inverter short circuit. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.31 |
| dupsPMStsINVSTSFail mandatory Indicates the power module Inverter STS fail. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.32 |
| dupsPMStsINVCircuitFail mandatory Indicates the power module Inverter circuit fail shutdown. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.33 |
| dupsPMStsINVOverVolt mandatory Indicates the power module Inverter over voltage shutdown. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.34 |
| dupsPMStsINVOverload mandatory Indicates the power module Inverter overload. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.35 |
| dupsPMStsINVInnerCommFail mandatory Indicates the power module Inverter inner communication fail. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.36 |
| dupsPMStsINVEPO mandatory Indicates the power module Inverter EPO shutdown. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.37 |
| dupsPMStsINVParallelCommFail mandatory Indicates the power module Inverter parallel communication fail. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.38 |
| dupsPMStsINVParallelFail mandatory Indicates the power module Inverter parallel fail. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.39 |
| dupsPMINVTempR mandatory The power module inverter-R temperature. | column | 1 Degree Celsius Integer32 | .1.3.6.1.4.1.2254.2.5.10.6.1.4 |
| dupsPMStsINVSTSOn mandatory Indicates the status of power module Inverter state. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.40 |
| dupsPMStsINVNotCalibrated mandatory Indicates the power module Inverter is not calibrated. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.41 |
| dupsPMStsChargerFail mandatory Indicates the power module Charger fail. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.42 |
| dupsPMSummaryStatus mandatory The power module summary status. | column | Enumeration | .1.3.6.1.4.1.2254.2.5.10.6.1.43 |
| dupsPMPFCTempR mandatory The power module pfc-R temperature. | column | 1 Degree Celsius Integer32 | .1.3.6.1.4.1.2254.2.5.10.6.1.44 |
| dupsPMPFCTempS mandatory The power module pfc-S temperature. | column | 1 Degree Celsius Integer32 | .1.3.6.1.4.1.2254.2.5.10.6.1.45 |
| dupsPMPFCTempT mandatory The power module pfc-T temperature. | column | 1 Degree Celsius Integer32 | .1.3.6.1.4.1.2254.2.5.10.6.1.46 |
| dupsPMINVTempS mandatory The power module inverter-S temperature. | column | 1 Degree Celsius Integer32 | .1.3.6.1.4.1.2254.2.5.10.6.1.5 |
| dupsPMINVTempT mandatory The power module inverter-T temperature. | column | 1 Degree Celsius Integer32 | .1.3.6.1.4.1.2254.2.5.10.6.1.6 |
| dupsPMINVVolt1 mandatory The inverter line 1 voltage of the power module in 1/10 V. | column | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.10.6.1.7 |
| dupsPMINVVolt2 mandatory The inverter line 2 voltage of the power module in 1/10 V. | column | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.10.6.1.8 |
| dupsPMINVVolt3 mandatory The inverter line 3 voltage of the power module in 1/10 V. | column | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.10.6.1.9 |