dupsOutputNumLines
DeltaUPSv5-MIB ·
.1.3.6.1.4.1.2254.2.5.5.3
Object
scalar
mandatory
Integer32
The number of output lines utilized in this device.
Context
- MIB
- DeltaUPSv5-MIB
- OID
.1.3.6.1.4.1.2254.2.5.5.3- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- dupsOutput
- Siblings
- 24
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dupsOutputSource mandatory The present source of output power. The enumeration
noOutput(8) indicates that there is no source of output
power (and therefore no output power), for example,
the system has open… | scalar | Enumeration | .1.3.6.1.4.1.2254.2.5.5.1 |
| dupsOutputVoltage23 mandatory The Output line 2-3 voltage of the UPS system in 1/10 V.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.5.10 |
| dupsOutputCurrent2 mandatory The Output line 2 current of the UPS system in 1/10 A.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Amp Integer32 | .1.3.6.1.4.1.2254.2.5.5.11 |
| dupsOutputPower2 mandatory The Output line 2 active power of the UPS system in watts.
The value -1 indicates this UPS does not support this item. | scalar | 1 Watt Integer32 | .1.3.6.1.4.1.2254.2.5.5.12 |
| dupsOutputLoad2 mandatory The current UPS output line 2 load expressed in percent
of rated capacity.
The value -1 indicates this UPS does not support this item. | scalar | 1 Percent Integer32 | .1.3.6.1.4.1.2254.2.5.5.13 |
| dupsOutputVoltage3 mandatory The Output phase 3 voltage of the UPS system in 1/10 V.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.5.14 |
| dupsOutputVoltage31 mandatory The Output line 3-1 voltage of the UPS system in 1/10 V.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.5.15 |
| dupsOutputCurrent3 mandatory The Output line 3 current of the UPS system in 1/10 A.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Amp Integer32 | .1.3.6.1.4.1.2254.2.5.5.16 |
| dupsOutputPower3 mandatory The Output line 3 active power of the UPS system in watts.
The value -1 indicates this UPS does not support this item. | scalar | 1 Watt Integer32 | .1.3.6.1.4.1.2254.2.5.5.17 |
| dupsOutputLoad3 mandatory The current UPS output line 3 load expressed in percent
of rated capacity.
The value -1 indicates this UPS does not support this item. | scalar | 1 Percent Integer32 | .1.3.6.1.4.1.2254.2.5.5.18 |
| dupsOutputTotalActivePower mandatory The total output active power of the UPS system in 0.1 kW.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 kW Integer32 | .1.3.6.1.4.1.2254.2.5.5.19 |
| dupsOutputFrequency mandatory The present output frequency in 1/10 Hz.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Hertz Integer32 | .1.3.6.1.4.1.2254.2.5.5.2 |
| dupsOutputTotalApparentPower mandatory The total output apparent power of the UPS system in 0.1 kVA.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 kVA Integer32 | .1.3.6.1.4.1.2254.2.5.5.20 |
| dupsOutputTotalPowerFactor mandatory The total output power factor of the UPS system.
The value -1 indicates this UPS does not support this item. | scalar | 1 Percent Integer32 | .1.3.6.1.4.1.2254.2.5.5.21 |
| dupsOutputEnergy1 mandatory The UPS output line 1 energy in kWh.
The value -1 indicates this UPS does not support this item. | scalar | 1 kWh Integer32 | .1.3.6.1.4.1.2254.2.5.5.22 |
| dupsOutputEnergy2 mandatory The UPS output line 2 energy in kWh.
The value -1 indicates this UPS does not support this item. | scalar | 1 kWh Integer32 | .1.3.6.1.4.1.2254.2.5.5.23 |
| dupsOutputEnergy3 mandatory The UPS output line 3 energy in kWh.
The value -1 indicates this UPS does not support this item. | scalar | 1 kWh Integer32 | .1.3.6.1.4.1.2254.2.5.5.24 |
| dupsOutputEnergyTotal mandatory The UPS total output energy in kWh.
The value -1 indicates this UPS does not support this item. | scalar | 1 kWh Integer32 | .1.3.6.1.4.1.2254.2.5.5.25 |
| dupsOutputVoltage1 mandatory The Output phase 1 voltage of the UPS system in 1/10 V.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.5.4 |
| dupsOutputVoltage12 mandatory The Output line 1-2 voltage of the UPS system in 1/10 V.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.5.5 |
| dupsOutputCurrent1 mandatory The Output line 1 current of the UPS system in 1/10 A.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Amp Integer32 | .1.3.6.1.4.1.2254.2.5.5.6 |
| dupsOutputPower1 mandatory The Output line 1 active power of the UPS system in watts.
The value -1 indicates this UPS does not support this item. | scalar | 1 Watt Integer32 | .1.3.6.1.4.1.2254.2.5.5.7 |
| dupsOutputLoad1 mandatory The current UPS output line 1 load expressed in percent
of rated capacity.
The value -1 indicates this UPS does not support this item. | scalar | 1 Percent Integer32 | .1.3.6.1.4.1.2254.2.5.5.8 |
| dupsOutputVoltage2 mandatory The Output phase 2 voltage of the UPS system in 1/10 V.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.5.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| IT-WATCHDOGS-V4-MIBthdSensorIndex Table entry index value | column | Integer32 | .1.3.6.1.4.1.17373.4.1.9.1.1 |