dupsInputPower1
DeltaUPSv5-MIB ·
.1.3.6.1.4.1.2254.2.5.4.6
Object
scalar
mandatory
1 Watt Integer32
The Input line 1 power to the UPS system in 1 Watt. The value -1 indicates this UPS does not support this item.
Context
- MIB
- DeltaUPSv5-MIB
- OID
.1.3.6.1.4.1.2254.2.5.4.6- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Units
- 1 Watt
- Parent
- dupsInput
- Siblings
- 21
Syntax
1 Watt Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dupsInputNumLines mandatory The number of input lines utilized in this device. | scalar | Integer32 | .1.3.6.1.4.1.2254.2.5.4.1 |
| dupsInputCurrent2 mandatory The Input line 2 current to the UPS system in 1/10 A.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Amp Integer32 | .1.3.6.1.4.1.2254.2.5.4.10 |
| dupsInputPower2 mandatory The Input line 2 power to the UPS system in 1 Watt.
The value -1 indicates this UPS does not support this item. | scalar | 1 Watt Integer32 | .1.3.6.1.4.1.2254.2.5.4.11 |
| dupsInputFrequency3 mandatory The current input line 3 frequency to the UPS system
in 1/10 Hz.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Hertz Integer32 | .1.3.6.1.4.1.2254.2.5.4.12 |
| dupsInputVoltage3 mandatory The Input phase 3 voltage of the UPS system in 1/10 V.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.4.13 |
| dupsInputVoltage31 mandatory The Input line 3-1 voltage of the UPS system in 1/10 V.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.4.14 |
| dupsInputCurrent3 mandatory The Input line 3 current to the UPS system in 1/10 A.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Amp Integer32 | .1.3.6.1.4.1.2254.2.5.4.15 |
| dupsInputPower3 mandatory The Input line 3 power to the UPS system in 1 Watt.
The value -1 indicates this UPS does not support this item. | scalar | 1 Watt Integer32 | .1.3.6.1.4.1.2254.2.5.4.16 |
| dupsInputEnergy1 mandatory The Input line 1 energy to the UPS system in 1 kWh.
The value -1 indicates this UPS does not support this item. | scalar | 1 kWh Integer32 | .1.3.6.1.4.1.2254.2.5.4.17 |
| dupsInputEnergy2 mandatory The Input line 2 energy to the UPS system in 1 kWh.
The value -1 indicates this UPS does not support this item. | scalar | 1 kWh Integer32 | .1.3.6.1.4.1.2254.2.5.4.18 |
| dupsInputEnergy3 mandatory The Input line 3 energy to the UPS system in 1 kWh.
The value -1 indicates this UPS does not support this item. | scalar | 1 kWh Integer32 | .1.3.6.1.4.1.2254.2.5.4.19 |
| dupsInputFrequency1 mandatory The current input line 1 frequency to the UPS
system in 1/10 Hz. The value -1 indicates this UPS does
not support this item. | scalar | 0.1 Hertz Integer32 | .1.3.6.1.4.1.2254.2.5.4.2 |
| dupsInputEnergyTotal mandatory The total Input energy to the UPS system in 1 kWh.
The value -1 indicates this UPS does not support this item. | scalar | 1 kWh Integer32 | .1.3.6.1.4.1.2254.2.5.4.20 |
| dupsInputLineFailCause mandatory Cause of input outage. | scalar | Enumeration | .1.3.6.1.4.1.2254.2.5.4.21 |
| dupsInputBadStatus mandatory Incorrect input voltage or frequency. | scalar | Enumeration | .1.3.6.1.4.1.2254.2.5.4.22 |
| dupsInputVoltage1 mandatory The Input phase 1 voltage of the UPS system in 1/10 V.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.4.3 |
| dupsInputVoltage12 mandatory The Input line 1-2 voltage of the UPS system in 1/10 V.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.4.4 |
| dupsInputCurrent1 mandatory The Input line 1 current to the UPS system in 1/10 A.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Amp Integer32 | .1.3.6.1.4.1.2254.2.5.4.5 |
| dupsInputFrequency2 mandatory The current input line 2 frequency to the UPS system
in 1/10 Hz.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Hertz Integer32 | .1.3.6.1.4.1.2254.2.5.4.7 |
| dupsInputVoltage2 mandatory The Input phase 2 voltage of the UPS system in 1/10 V.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.4.8 |
| dupsInputVoltage23 mandatory The Input line 2-3 voltage of the UPS system in 1/10 V.
The value -1 indicates this UPS does not support this item. | scalar | 0.1 Volt Integer32 | .1.3.6.1.4.1.2254.2.5.4.9 |