dupsControl
DeltaUPSv5-MIB ·
.1.3.6.1.4.1.2254.2.5.2
Object
node
No description available.
Context
- MIB
- DeltaUPSv5-MIB
- OID
.1.3.6.1.4.1.2254.2.5.2- Type
- node
- Parent
- upsv5
- Siblings
- 13
- Children
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dupsIdent | node | - | .1.3.6.1.4.1.2254.2.5.1 |
| dupsPowerModule | node | - | .1.3.6.1.4.1.2254.2.5.10 |
| dupsTrapArgs | node | - | .1.3.6.1.4.1.2254.2.5.11 |
| dupsParallel | node | - | .1.3.6.1.4.1.2254.2.5.12 |
| dupsIntegrated | node | - | .1.3.6.1.4.1.2254.2.5.13 |
| dupsTraps | node | - | .1.3.6.1.4.1.2254.2.5.20 |
| dupsConfig | node | - | .1.3.6.1.4.1.2254.2.5.3 |
| dupsInput | node | - | .1.3.6.1.4.1.2254.2.5.4 |
| dupsOutput | node | - | .1.3.6.1.4.1.2254.2.5.5 |
| dupsBypass | node | - | .1.3.6.1.4.1.2254.2.5.6 |
| dupsBattery | node | - | .1.3.6.1.4.1.2254.2.5.7 |
| dupsTest | node | - | .1.3.6.1.4.1.2254.2.5.8 |
| dupsAlarm | node | - | .1.3.6.1.4.1.2254.2.5.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dupsShutdownType mandatory This object determines the nature of the action to be
taken at the time when the countdown of the
upsShutdownAfterDelay and upsRebootWithDuration
objects reaches zero.
Setting thi… | scalar | Enumeration | .1.3.6.1.4.1.2254.2.5.2.1 |
| dupsAutoReboot mandatory In backup mode, the UPS may shutdown normally by SDA command,
dry-contact remote shutdown signal or low battery shutdown.
This command is used to determine the unit should resta… | scalar | Enumeration | .1.3.6.1.4.1.2254.2.5.2.2 |
| dupsShutdownAction mandatory If the value is greater than 0 the UPS performs
shutdown action that defined by ShutdownType after
the seconds. 0, aborted. | scalar | Integer32 | .1.3.6.1.4.1.2254.2.5.2.3 |
| dupsRestartAction mandatory UPS will restart after the indicated number of minutes.
-1, aborted. | scalar | Integer32 | .1.3.6.1.4.1.2254.2.5.2.4 |
| dupsSetOutletRelay mandatory Indicate which outlet relay, from 1,2,3... . | scalar | Integer32 | .1.3.6.1.4.1.2254.2.5.2.5 |
| dupsRelayOffDelay mandatory Turn the relay off after the seconds. The relay was indicated
by SetOutletRelay. | scalar | Integer32 | .1.3.6.1.4.1.2254.2.5.2.6 |
| dupsRelayOnDelay mandatory Turn the relay on after the minutes. The relay was indicated
by SetOutletRelay. | scalar | Integer32 | .1.3.6.1.4.1.2254.2.5.2.7 |
| dupsSmartShutdown mandatory Any value to initiate the Smart Shutdown for the UPS. | scalar | Integer32 | .1.3.6.1.4.1.2254.2.5.2.8 |
| dupsClearEnergy mandatory Any value to clear the energy record in the UPS. | scalar | Integer32 | .1.3.6.1.4.1.2254.2.5.2.9 |