dupsConfig
DeltaUPSv5-MIB ·
.1.3.6.1.4.1.2254.2.5.3
Object
node
No description available.
Context
- MIB
- DeltaUPSv5-MIB
- OID
.1.3.6.1.4.1.2254.2.5.3- Type
- node
- Parent
- upsv5
- Siblings
- 13
- Children
- 10
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dupsIdent | node | - | .1.3.6.1.4.1.2254.2.5.1 |
| dupsPowerModule | node | - | .1.3.6.1.4.1.2254.2.5.10 |
| dupsTrapArgs | node | - | .1.3.6.1.4.1.2254.2.5.11 |
| dupsParallel | node | - | .1.3.6.1.4.1.2254.2.5.12 |
| dupsIntegrated | node | - | .1.3.6.1.4.1.2254.2.5.13 |
| dupsControl | node | - | .1.3.6.1.4.1.2254.2.5.2 |
| dupsTraps | node | - | .1.3.6.1.4.1.2254.2.5.20 |
| dupsInput | node | - | .1.3.6.1.4.1.2254.2.5.4 |
| dupsOutput | node | - | .1.3.6.1.4.1.2254.2.5.5 |
| dupsBypass | node | - | .1.3.6.1.4.1.2254.2.5.6 |
| dupsBattery | node | - | .1.3.6.1.4.1.2254.2.5.7 |
| dupsTest | node | - | .1.3.6.1.4.1.2254.2.5.8 |
| dupsAlarm | node | - | .1.3.6.1.4.1.2254.2.5.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dupsConfigBuzzerAlarm mandatory UPS will keep silence but will alarm again when
next power event is occurred | scalar | Enumeration | .1.3.6.1.4.1.2254.2.5.3.1 |
| dupsConfigEconomicMode mandatory Used to enable or disable the economic mode. | scalar | Enumeration | .1.3.6.1.4.1.2254.2.5.3.10 |
| dupsConfigBuzzerState mandatory If it is disabled then the UPS is always muted. | scalar | Enumeration | .1.3.6.1.4.1.2254.2.5.3.2 |
| dupsConfigSensitivity mandatory The seneitivity of the UPS to utility line
abnormalities or noises. | scalar | Enumeration | .1.3.6.1.4.1.2254.2.5.3.3 |
| dupsConfigLowVoltageTransferPoint mandatory The minimum input line voltage allowed before the UPS
system transfers to battery backup. | scalar | Volt Integer32 | .1.3.6.1.4.1.2254.2.5.3.4 |
| dupsConfigHighVoltageTransferPoint mandatory The maximum line voltage allowed before the UPS
system transfers to battery backup. | scalar | Volt Integer32 | .1.3.6.1.4.1.2254.2.5.3.5 |
| dupsConfigUPSBootDelay mandatory Delay the UPS startup after power restores. The power
quality may not stable when power restores, this
feature let the UPS wait a period of time to startup
the system. | scalar | Second Integer32 | .1.3.6.1.4.1.2254.2.5.3.6 |
| dupsConfigExternalBatteryPack mandatory Indicate the number of external battery pack. | scalar | Integer32 | .1.3.6.1.4.1.2254.2.5.3.7 |
| dupsConfigSmartShutdownOSDelay mandatory The estimated operating system shutdown delay time for
Smart Shutdown. | scalar | Second Integer32 | .1.3.6.1.4.1.2254.2.5.3.8 |
| dupsConfigSmartShutdownUPSDelay mandatory The estimated UPS shutdown delay time for
Smart Shutdown. | scalar | Second Integer32 | .1.3.6.1.4.1.2254.2.5.3.9 |