docsIf3CmSpectrumAnalysisCtrlCmdSegmentFrequencySpan
DOCS-IF3-MIB ·
.1.3.6.1.4.1.4491.2.1.20.1.34.5
Object
scalar
r/w
Hz Unsigned32
This attribute controls the frequency span of each
segment (instance) in the docsIf3CmSpectrumAnalysisMeasTable.
If set to a value of 0, then a default span will be
chosen based on the hardware capabilities of the
device. Segments are contiguous from the
FirstSegementCenterFrequency to the
LastSegmentCenterFrequency and the center frequency
for each successive segment is incremented by the
SegmentFequencySpan.
The number of segments is (LastSegmentCenterFrequency -
FirstSegmentCenterFrequency)/SegmentFrequencySpan + 1.
A segment is equivalent to an instance in the
docsIf3CmSpectrumAnalysisMeasTable. The chosen
SegmentFrequencySpan affects the number of entries in
the docsIf3CmSpectrumAnalysisMeasTable. A more granular
SegmentFrequencySpan may adversely affect the amount of
time needed to query the table entries in addition to
possibly increasing the acquisition time.
Changing the value of this attribute may result in
changes to the docsIf3CmSpectrumAnalysisMeasTable.
Note that if this attribute is set to an invalid value,
the device may return an error, or may adjust the value
of the object to the closest valid value.
Context
- MIB
- DOCS-IF3-MIB
- OID
.1.3.6.1.4.1.4491.2.1.20.1.34.5- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- Hz
- Parent
- docsIf3CmSpectrumAnalysisCtrlCmd
- Siblings
- 8
Syntax
Hz Unsigned32
Values & Constraints
Object Constraints
range: 1000000-900000000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| docsIf3CmSpectrumAnalysisCtrlCmdEnable This attribute is used to enable or disable the spectrum
analyzer feature. Setting this attribute to true triggers the CM
to initiate measurements for the spectrum analyzer featur… | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.4491.2.1.20.1.34.1 |
| docsIf3CmSpectrumAnalysisCtrlCmdInactivityTimeout This attribute controls the length of time after the last
spectrum analysis measurement before the feature is
automatically disabled. If set to a value of 0, the feature will
rema… | scalar | seconds Integer32 | .1.3.6.1.4.1.4491.2.1.20.1.34.2 |
| docsIf3CmSpectrumAnalysisCtrlCmdFirstSegmentCenterFrequency This attribute controls the center frequency of the
first segment for the spectrum analysis measurement.
The frequency bins for this segment lie symmetrically
to the left and righ… | scalar | Hz SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.3 |
| docsIf3CmSpectrumAnalysisCtrlCmdLastSegmentCenterFrequency This attribute controls the center frequency of
the last segment of the spectrum analysis measurement.
The frequency bins for this segment lie symmetrically
to the left… | scalar | Hz SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.4 |
| docsIf3CmSpectrumAnalysisCtrlCmdNumBinsPerSegment This attribute controls the number of bins collected
by the measurement performed for each segment (instance)
in the docsIf3CmSpectrumAnalysisMeasTable.
Note that if th… | scalar | bins-per-segment Unsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.6 |
| docsIf3CmSpectrumAnalysisCtrlCmdEquivalentNoiseBandwidth This attribute allows the user to request an equivalent
noise bandwidth for the resolution bandwidth filter used
in the spectrum analysis. This corresponds to the
spectral width … | scalar | hundredthsbin Unsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.7 |
| docsIf3CmSpectrumAnalysisCtrlCmdWindowFunction This attribute controls or indicates the windowing function
which will be used when performing the discrete Fourier
transform for the analysis. The WindowFunction and the
Equival… | scalar | SpectrumAnalysisWindowFunction | .1.3.6.1.4.1.4491.2.1.20.1.34.8 |
| docsIf3CmSpectrumAnalysisCtrlCmdNumberOfAverages This attribute controls the number of averages
that will be performed on spectral bins.
The average will be computed using the 'leaky integrator'
method, where: