docsIf3CmSpectrumAnalysisCtrlCmdNumBinsPerSegment
DOCS-IF3-MIB ·
.1.3.6.1.4.1.4491.2.1.20.1.34.6
Object
scalar
r/w
bins-per-segment Unsigned32
This attribute controls the number of bins collected
by the measurement performed for each segment (instance)
in the docsIf3CmSpectrumAnalysisMeasTable.
Note that if this attribute is set to an invalid value,
the device may return an error, or may adjust the value
of the attribute to the closest valid value.
Context
- MIB
- DOCS-IF3-MIB
- OID
.1.3.6.1.4.1.4491.2.1.20.1.34.6- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- bins-per-segment
- Parent
- docsIf3CmSpectrumAnalysisCtrlCmd
- Siblings
- 8
Syntax
bins-per-segment Unsigned32
Values & Constraints
Object Constraints
range: 2-2048
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| docsIf3CmSpectrumAnalysisCtrlCmdEnable This attribute is used to enable or disable the spectrum
analyzer feature. Setting this attribute to true triggers the CM
to initiate measurements for the spectrum analyzer featur… | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.4491.2.1.20.1.34.1 |
| docsIf3CmSpectrumAnalysisCtrlCmdInactivityTimeout This attribute controls the length of time after the last
spectrum analysis measurement before the feature is
automatically disabled. If set to a value of 0, the feature will
rema… | scalar | seconds Integer32 | .1.3.6.1.4.1.4491.2.1.20.1.34.2 |
| docsIf3CmSpectrumAnalysisCtrlCmdFirstSegmentCenterFrequency This attribute controls the center frequency of the
first segment for the spectrum analysis measurement.
The frequency bins for this segment lie symmetrically
to the left and righ… | scalar | Hz SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.3 |
| docsIf3CmSpectrumAnalysisCtrlCmdLastSegmentCenterFrequency This attribute controls the center frequency of
the last segment of the spectrum analysis measurement.
The frequency bins for this segment lie symmetrically
to the left… | scalar | Hz SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.4 |
| docsIf3CmSpectrumAnalysisCtrlCmdSegmentFrequencySpan This attribute controls the frequency span of each
segment (instance) in the docsIf3CmSpectrumAnalysisMeasTable.
If set to a value of 0, then a default span will be
cho… | scalar | Hz Unsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.5 |
| docsIf3CmSpectrumAnalysisCtrlCmdEquivalentNoiseBandwidth This attribute allows the user to request an equivalent
noise bandwidth for the resolution bandwidth filter used
in the spectrum analysis. This corresponds to the
spectral width … | scalar | hundredthsbin Unsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.7 |
| docsIf3CmSpectrumAnalysisCtrlCmdWindowFunction This attribute controls or indicates the windowing function
which will be used when performing the discrete Fourier
transform for the analysis. The WindowFunction and the
Equival… | scalar | SpectrumAnalysisWindowFunction | .1.3.6.1.4.1.4491.2.1.20.1.34.8 |
| docsIf3CmSpectrumAnalysisCtrlCmdNumberOfAverages This attribute controls the number of averages
that will be performed on spectral bins.
The average will be computed using the 'leaky integrator'
method, where:
reported bin val… | scalar | Unsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.9 |