docsIf3CmSpectrumAnalysisCtrlCmdEnable
DOCS-IF3-MIB ·
.1.3.6.1.4.1.4491.2.1.20.1.34.1
Object
This attribute is used to enable or disable the spectrum
analyzer feature. Setting this attribute to true triggers the CM
to initiate measurements for the spectrum analyzer feature based
on the other configuration attributes for the feature. By
default, the feature is disabled unless explicitly enabled.
Note that the feature may be disabled by the system under
certain circumstances if the spectrum analyzer would affect
critical services. In such a case, the attribute will return
'false' when read, and will reject sets to 'true' with an
error. Once the feature is enabled, any Set operation on
the docsIf3CmSpectrumAnalysisCtrlCmd MIB group might not
be effective until the feature is re-enabled again.
Context
- MIB
- DOCS-IF3-MIB
- OID
.1.3.6.1.4.1.4491.2.1.20.1.34.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- docsIf3CmSpectrumAnalysisCtrlCmd
- Siblings
- 8
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| docsIf3CmSpectrumAnalysisCtrlCmdInactivityTimeout This attribute controls the length of time after the last
spectrum analysis measurement before the feature is
automatically disabled. If set to a value of 0, the feature will
rema… | scalar | seconds Integer32 | .1.3.6.1.4.1.4491.2.1.20.1.34.2 |
| docsIf3CmSpectrumAnalysisCtrlCmdFirstSegmentCenterFrequency This attribute controls the center frequency of the
first segment for the spectrum analysis measurement.
The frequency bins for this segment lie symmetrically
to the left and righ… | scalar | Hz SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.3 |
| docsIf3CmSpectrumAnalysisCtrlCmdLastSegmentCenterFrequency This attribute controls the center frequency of
the last segment of the spectrum analysis measurement.
The frequency bins for this segment lie symmetrically
to the left… | scalar | Hz SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.4 |
| docsIf3CmSpectrumAnalysisCtrlCmdSegmentFrequencySpan This attribute controls the frequency span of each
segment (instance) in the docsIf3CmSpectrumAnalysisMeasTable.
If set to a value of 0, then a default span will be
cho… | scalar | Hz Unsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.5 |
| docsIf3CmSpectrumAnalysisCtrlCmdNumBinsPerSegment This attribute controls the number of bins collected
by the measurement performed for each segment (instance)
in the docsIf3CmSpectrumAnalysisMeasTable.
Note that if th… | scalar | bins-per-segment Unsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.6 |
| docsIf3CmSpectrumAnalysisCtrlCmdEquivalentNoiseBandwidth This attribute allows the user to request an equivalent
noise bandwidth for the resolution bandwidth filter used
in the spectrum analysis. This corresponds to the
spectral width … | scalar | hundredthsbin Unsigned32 | .1.3.6.1.4.1.4491.2.1.20.1.34.7 |
| docsIf3CmSpectrumAnalysisCtrlCmdWindowFunction This attribute controls or indicates the windowing function
which will be used when performing the discrete Fourier
transform for the analysis. The WindowFunction and the
Equival… | scalar | SpectrumAnalysisWindowFunction | .1.3.6.1.4.1.4491.2.1.20.1.34.8 |
| docsIf3CmSpectrumAnalysisCtrlCmdNumberOfAverages This attribute controls the number of averages
that will be performed on spectral bins.
The average will be computed using the 'leaky integrator'
method, where: