erpsProfileHoldOffTimer

DLINK-DXS-1210-10TS-AX-MIB · .1.3.6.1.4.1.171.10.139.2.1.4.10.2.1.1.5

Object

column r/w milliseconds Unsigned32
This object is used to configure the period for the hold-off timer.
              
Hold-Off timer will be started when a new defect (SF) is received for 
  	this ring.  This defect will not be given as local SF to ERP control 
  	process until Hold-Off timer expires.
              
  	When the Hold-Off timer expires and if a local defect still exists, it
  	will be given as local SF to the ERPS control process of this ring.

Context

MIB
DLINK-DXS-1210-10TS-AX-MIB
OID
.1.3.6.1.4.1.171.10.139.2.1.4.10.2.1.1.5
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
erpsProfileEntry
Table
erpsProfileTable
Siblings
6

Syntax

milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 0-10000