isisSdEntMapHostnames

DC-ISIS-MIB · .1.3.6.1.4.1.629.10.10.1.12.1.1.5

Object

column r/w SNMPv2-TCTruthValue
Should SDC map system IDs to hostnames?
              
If 'true', SDC will fill in the isisISAdjNeighHostname and
isisISAdjNeighLanIDHostname objects (if a hostname is
known), and will map system IDs to hostnames in PD logs.
              
Setting this object to 'true' will cause a small occupancy
increase, because SDC will set up a database of mappings between
the system IDs and the corresponding hostnames.

Context

MIB
DC-ISIS-MIB
OID
.1.3.6.1.4.1.629.10.10.1.12.1.1.5
Type
column
Access
readwrite
Status
current
Parent
isisSdEntEntry
Table
isisSdEntTable
Siblings
7

Syntax

SNMPv2-TCTruthValue
Source
SNMPv2-TCTruthValue
Base type
Enumeration

Values & Constraints

Type Values
1true
2false

Related Objects

Sibling Objects