ds1AlarmGlobalBPVInterval
CTRON-WAN-MIB ·
.1.3.6.1.4.1.52.4.1.2.7.1.6.1.7
Object
scalar
mandatory
r/w
Integer32
Used to specify the interval, used in monitoring Bipolar Violations (Code Violations for E1) with thresholds defined by ds1AlarmGlobalBPVErrorRate. For example, for a ds1AlarmGlobalBPVErrorRate value of 6 used with a ds1AlarmGlobalBPVInterval of 15, an alarm is generated when a 15 minute period has an average error rate which exceeds 1 Bipolar Violation (Code Violation for E1) per million bits. For those devices that support ds1 alarm monitoring but who's hardware does not detect bipolar violations, this object always returns the default, and performs no action when written.
Context
- MIB
- CTRON-WAN-MIB
- OID
.1.3.6.1.4.1.52.4.1.2.7.1.6.1.7- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- ds1AlarmsGlobalConfigGroup
- Siblings
- 7
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-15
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ds1AlarmGlobalAdmin mandatory Used to enable and disable the DS1 Alarm
Monitoring Application for all DS1 circuits on the
device. | scalar | Enumeration | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.1 |
| ds1AlarmGlobalAutoRecovery mandatory Used to enable and disable the DS1 Alarm
Automatic Recovery feature for all DS1 circuits on
the device. For those devices that support ds1
alarm monitoring, but do not support th… | scalar | Enumeration | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.2 |
| ds1AlarmGlobalTrapEnable mandatory Used to enable and disable the DS1 Alarm
SNMP Trap generation feature for all DS1 circuits on
the device. This object operates in conjunction with
configuration of objects in t… | scalar | Enumeration | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.3 |
| ds1AlarmGlobalESCount mandatory Used in conjuction with ctDs1AlarmESInterval to set
the threshold for alarm generation when the number of
Errored Seconds for a specified time interval,
measured in minutes, is… | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.4 |
| ds1AlarmGlobalESInterval mandatory Used in conjuction with ds1AlarmGlobalESCount to
set the threshold for alarm generation when the number
of Errored Seconds for a specified time interval,
measured in minutes, i… | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.5 |
| ds1AlarmGlobalBPVErrorRate mandatory Used to specify the negative exponent of 10, used in
monitoring Bipolar Violations (Code Violations for E1)
over intervals defined by ds1AlarmGlobalBPVInterval.
For example, for… | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.6 |
| ds1AlarmGlobalManualRecovery mandatory To cause a manual recovery to occur on all Ds1 circuits, this
object is set to a 1. It is always read as a 1. The recovery