ds1AlarmGlobalAutoRecovery
CTRON-WAN-MIB ·
.1.3.6.1.4.1.52.4.1.2.7.1.6.1.2
Object
scalar
mandatory
r/w
Enumeration
Used to enable and disable the DS1 Alarm Automatic Recovery feature for all DS1 circuits on the device. For those devices that support ds1 alarm monitoring, but do not support the automatic recovery feature, this object always returns disabled, and performs no action when written.
Context
- MIB
- CTRON-WAN-MIB
- OID
.1.3.6.1.4.1.52.4.1.2.7.1.6.1.2- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- ds1AlarmsGlobalConfigGroup
- Siblings
- 7
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | disabled |
2 | enabled |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ds1AlarmGlobalAdmin mandatory Used to enable and disable the DS1 Alarm
Monitoring Application for all DS1 circuits on the
device. | scalar | Enumeration | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.1 |
| ds1AlarmGlobalTrapEnable mandatory Used to enable and disable the DS1 Alarm
SNMP Trap generation feature for all DS1 circuits on
the device. This object operates in conjunction with
configuration of objects in t… | scalar | Enumeration | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.3 |
| ds1AlarmGlobalESCount mandatory Used in conjuction with ctDs1AlarmESInterval to set
the threshold for alarm generation when the number of
Errored Seconds for a specified time interval,
measured in minutes, is… | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.4 |
| ds1AlarmGlobalESInterval mandatory Used in conjuction with ds1AlarmGlobalESCount to
set the threshold for alarm generation when the number
of Errored Seconds for a specified time interval,
measured in minutes, i… | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.5 |
| ds1AlarmGlobalBPVErrorRate mandatory Used to specify the negative exponent of 10, used in
monitoring Bipolar Violations (Code Violations for E1)
over intervals defined by ds1AlarmGlobalBPVInterval.
For example, for… | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.6 |
| ds1AlarmGlobalBPVInterval mandatory Used to specify the interval, used in monitoring
Bipolar Violations (Code Violations for E1)
with thresholds defined by ds1AlarmGlobalBPVErrorRate.
For example, for a ds1AlarmGlo… | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.7 |
| ds1AlarmGlobalManualRecovery mandatory To cause a manual recovery to occur on all Ds1 circuits, this
object is set to a 1. It is always read as a 1. The recovery
will occur only when automatic recovery is disabled. | scalar | Enumeration | .1.3.6.1.4.1.52.4.1.2.7.1.6.1.8 |