ctRemPhysPortProtMgrType
CTRON-REMOTE-ACCESS-MIB ·
.1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.4
Object
column
mandatory
r/w
Enumeration
This object identifies an instance of the type of Protocol Manager residing on this physical port. Before a physical port may be used, the type of manager must be designated. For example, if the physical port was going to be used as an ISDN PRI interface, with dial up PPP links, then the manager type would be set to (4), ISDN-PRI-PPP.
Context
- MIB
- CTRON-REMOTE-ACCESS-MIB
- OID
.1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.4- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- ctRemPhysPortEntry
- Table
- ctRemPhysPortTable
- Siblings
- 9
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | none |
2 | pppNailedUp |
3 | isdnPriPpp |
4 | isdnBriPpp |
5 | frameRelayPvcRtr |
6 | frameRelayPvcSw |
7 | hdlc |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ctRemConnectionIndex mandatory A value indicating the remote connection this entry
is located on. | column | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.1 |
| ctRemPhysWpimType mandatory This Mib object determines the Mode of operation that
the T1/DDS Wpim module will function as. Setting a value
of 1 will set the mode to DDS, setting a value of 2 will
set the mod… | column | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.10 |
| ctRemPhysPortType mandatory The type of physical port that this entry describes. None
indicates that the physical port has no connector. | column | Enumeration | .1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.2 |
| ctRemPhysPortSpecificMib mandatory This object identifies an instance of the
index object in the first group of objects in the
MIB specific to the physical port. | column | ObjectIdentifier | .1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.3 |
| ctRemPhysPortProtMgrIfaceNum mandatory This object identifies the interface number that
will be assigned to the Protocol Managers IFO | column | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.5 |
| ctRemPhysPortWanIfaceNum mandatory This object identifies the interface number that
will be assigned to the Wanio's IFO | column | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.6 |
| ctRemPhysPortProtMgrMaxIfos mandatory This object identifies the maximum number of IFO's
that can be created on this physical interface. | column | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.7 |
| ctRemPhysPortProtMgrIfaceList mandatory This object identifies a list of interfaces that
will be assigned to this Protocol Managers data IFO's | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.8 |
| ctRemPhysAlarmTimeOut mandatory Whenever the physical port is configured for nailed-up
PPP this object specifies the time the physical port
must remain in a failed state as a condition to begin
the backup pro… | column | Integer32 | .1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.9 |