ePDUIdentDeviceRating
CPS-MIB ·
.1.3.6.1.4.1.3808.1.1.3.1.7
Object
scalar
mandatory
Integer32
Getting this OID will return the electrical rating of the device.
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ePDUIdentName mandatory The name of the Rack PDU.
The maximum string size is device dependent. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.3.1.1 |
| ePDUIdentDeviceNumBreakers mandatory Getting this OID will return the number of circuit breakers supported by the device.
This is the same as the number of banks of outlets.
0 will be returned if the unit has no phas… | scalar | Integer32 | .1.3.6.1.4.1.3808.1.1.3.1.10 |
| ePDUIdentDeviceBreakerRating mandatory Getting this OID will return rating of the circuit breakers on the device if it has any. | scalar | Integer32 | .1.3.6.1.4.1.3808.1.1.3.1.11 |
| ePDUIdentDeviceOrientation mandatory Getting this OID will return the intended physical orientation of the device.
OrientHorizonatal(1) indicates Horizontal.
OrientVertical(2) indicates Vertical. | scalar | Enumeration | .1.3.6.1.4.1.3808.1.1.3.1.12 |
| ePDUIdentDeviceOutletLayout mandatory Getting this OID will return outlet layout for the device.
SeqPhaseToNeutral(1) indicates outlet layout as follows:
1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
SeqPhas… | scalar | Enumeration | .1.3.6.1.4.1.3808.1.1.3.1.13 |
| ePDUIdentDeviceDisplayOrientation mandatory Getting this OID will return the intended physical orientation of the Seven-Segment Display.
displayNormal(1) indicates Normal.
displayReverse(2)indicates Upside-Down.
… | scalar | Enumeration | .1.3.6.1.4.1.3808.1.1.3.1.14 |
| ePDUIdentDeviceLinetoLineVoltage mandatory Getting/Setting this OID will return/set the Line to Line Volatage.
The valid range is between 0V to 440V | scalar | Integer32 | .1.3.6.1.4.1.3808.1.1.3.1.15 |
| ePDUIdentIndicator mandatory PDU will perform a panel indicator test when the variable
is set to testIndicators(2).
It is no effective to set this value to noTestIndicators(1). | scalar | Enumeration | .1.3.6.1.4.1.3808.1.1.3.1.16 |
| ePDUIdentHardwareRev mandatory The hardware revision of the Rack PDU.
This value is set at the factory. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.3.1.2 |
| ePDUIdentFirmwareRev mandatory An 8-byte ID string identifying the Rack PDU firmware revision.
This value is set at the factory. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.3.1.3 |
| ePDUIdentDateOfManufacture mandatory The date when the Rack PDU was manufactured in mm/dd/yyyy format.
This value is set at the factory. The year 2000 will be
represented by 00. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.3.1.4 |
| ePDUIdentModelNumber mandatory A 10-character string identifying the model number of
the Rack PDU. This value is set at the factory. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.3.1.5 |
| ePDUIdentSerialNumber mandatory A 12-character string identifying the serial number of
the Rack PDU. This value is set at the factory. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.3.1.6 |
| ePDUIdentDeviceNumOutlets mandatory Getting this OID will return the number of outlets contained in the device. | scalar | Integer32 | .1.3.6.1.4.1.3808.1.1.3.1.8 |
| ePDUIdentDeviceNumPhases mandatory Getting this OID will return the number of phases supported by the device. | scalar | Integer32 | .1.3.6.1.4.1.3808.1.1.3.1.9 |