waterCoolUnitOutputType
CPQWCRM-MIB ·
.1.3.6.1.4.1.232.167.2.4.6.2.1.2
Object
column
mandatory
Enumeration
Type of output which is connected to water cool unit to output[waterCoolUnitOutputIndex] 1: no output connected 2: output failure 3: value overflow 4: water valve setpoint 5: water valve hysteresis 6: command for manual control 7: Flow Meter Model, 0=SIKA, 1=Chemline 8: minimum fan speed 9: min delta T, used for fan control 10: max delta T, used for fan control 11: specific heat capacity 12: setpoint heatload warning 13: setpoint Water Flow Loss Emergency Door Opening 14: setpoint High Temperature Emergency Door Opening 15: setpoint Condensation Pump Cycles (Warning) 16: setpoint Condensation Pump Running Time (Warning) 17: command for door opening, 0=lock door, 1=unlock door 18: KP parameter for PID controller 19: KI parameter for PID controller 20: KD parameter for PID controller 21: sampling time PID controller 22: number of installed fans 23: offset for cold water temperature 24: offset for hot water temperature 25: valve control mode 26: isolation valve inlet, manual control 27: isolation valve facility, manual control 28: isolation valve infrastructure, manual control 29: control valve facility, manual setting 30: control valve infrastructure, manual setting 31: fan control mode 32: fan 1, manual setting 33: fan 2, manual setting 34: fan 3, manual setting 35: fan 4: manual setting 36: setpoint for air difference pressure (fan control), this value is scaled with 1000 (e. g. 0.1 inch H2O are entered as 100) 37: KP parameter for Fan PID controller 38: KI parameter for Fan PID controller 39: KD parameter for Fan PID controller 40: sampling time Fan PID controller 41: dewpoint Offset for dewpoint average Value 42: max IT Air Temperature, Limit for dewpoint control 43: dewpoint control mode, 0 = off, 1 = On
Context
- MIB
- CPQWCRM-MIB
- OID
.1.3.6.1.4.1.232.167.2.4.6.2.1.2- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqWcrmWaterCoolUnitOutputEntry
- Table
- cpqWcrmWaterCoolUnitOutputTable
- Siblings
- 8
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | notAvail |
2 | failure |
3 | overflow |
4 | setpoint |
5 | hysteresis |
6 | command |
7 | controlMode |
8 | fanSpeedMin |
9 | dTmin |
10 | dTmax |
11 | cpWatert |
12 | setHeatload |
13 | setEdoFlow |
14 | setEdoHeat |
15 | setCondCycles |
16 | setCondRun |
17 | doorControl |
18 | pidContrKP |
19 | pidContrKI |
20 | pidContrKD |
21 | pidSampleTime |
22 | installedFans |
23 | offsetCW |
24 | offsetHW |
25 | valveControlMode |
26 | isolationValveInletManual |
27 | isolationValveFacilityManual |
28 | isolationValveInfrastructureManual |
29 | controlValveFacilityManual |
30 | controlValveInfrastructureManual |
31 | fanControlMode |
32 | fan1Manual |
33 | fan2Manual |
34 | fan3Manual |
35 | fan4Manual |
36 | setpointAirDifPressure |
37 | pidContrKPFan |
38 | pidContrKIFan |
39 | pidContrKDFan |
40 | pidSampleTimeFan |
41 | dewpointOffset |
42 | maxItAirTemperature |
43 | dewpointControlMode |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| waterCoolUnitOutputIndex mandatory Index for the list of output entries. Its value ranges
between 1 and the value of cpqWcrmWaterCoolUnitNumberOfOutputs. | column | Integer32 | .1.3.6.1.4.1.232.167.2.4.6.2.1.1 |
| waterCoolUnitOutputText mandatory Descriptional text for each output (entry in the table) | column | OctetString | .1.3.6.1.4.1.232.167.2.4.6.2.1.3 |
| waterCoolUnitOutputStatus mandatory Actual status of the output | column | Enumeration | .1.3.6.1.4.1.232.167.2.4.6.2.1.4 |
| waterCoolUnitOutputValue mandatory Signed value for output | column | Integer32 | .1.3.6.1.4.1.232.167.2.4.6.2.1.5 |
| waterCoolUnitOutputSet mandatory Command for output | column | Enumeration | .1.3.6.1.4.1.232.167.2.4.6.2.1.6 |
| waterCoolUnitOutputConfig mandatory Configuration for output
1: disable remote control (e.g. keypad)
2: enable remote control | column | Enumeration | .1.3.6.1.4.1.232.167.2.4.6.2.1.7 |
| waterCoolUnitOutputDelay mandatory Unsigned Value for delay,
after this time the output will fall into the previous state | column | Integer32 | .1.3.6.1.4.1.232.167.2.4.6.2.1.8 |
| waterCoolUnitOutputTimeoutAction mandatory State for output if timeout (RS422) occurs | column | Enumeration | .1.3.6.1.4.1.232.167.2.4.6.2.1.9 |