pdu3InputPhaseCurrent
CPQPOWER-MIB ·
.1.3.6.1.4.1.232.165.11.2.2.1.11
Object
column
mandatory
Integer32
An input current measurement value. Return value is divided by 100.
Context
- MIB
- CPQPOWER-MIB
- OID
.1.3.6.1.4.1.232.165.11.2.2.1.11- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- pdu3InputPhaseEntry
- Table
- pdu3InputPhaseTable
- Siblings
- 23
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pdu3InputPhaseIndex mandatory Index for the Pdu3InputEntry table. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.1 |
| pdu3InputPhaseCurrentRating mandatory Rated current capacity of the input. A negative value indicates that
the hardware current capacity is unknown. Return value is divided by 100. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.10 |
| pdu3InputPhaseCurrentThStatus mandatory Status of the measured input current relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.232.165.11.2.2.1.12 |
| pdu3InputPhaseCurrentThLowerWarning mandatory Lower warning threshold. Return value is divided by 100. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.13 |
| pdu3InputPhaseCurrentThLowerCritical mandatory Lower critical threshold. Return value is divided by 100. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.14 |
| pdu3InputPhaseCurrentThUpperWarning mandatory Upper warning threshold. Return value is divided by 100. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.15 |
| pdu3InputPhaseCurrentThUpperCritical mandatory Upper critical threshold. Return value is divided by 100. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.16 |
| pdu3InputPhaseCurrentPercentLoad mandatory Current percent load, based on the rated current capacity. Units are
percentage, for example 80.9 % will be returned as 809. A negative
value indicates that this object is not a… | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.17 |
| pdu3InputPhasePowerMeasType mandatory Which input wire is being measured in this table row - single phase, neutral, phase 1,
phase 2, or phase 3. | column | Enumeration | .1.3.6.1.4.1.232.165.11.2.2.1.18 |
| pdu3InputPhasePowerVA mandatory An input VA value. Units are VA. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.19 |
| pdu3InputPhaseVoltageMeasType mandatory Value indicates what input voltage is being measured in this table row - single phase
voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2,
phas… | column | Enumeration | .1.3.6.1.4.1.232.165.11.2.2.1.2 |
| pdu3InputPhasePowerWatts mandatory An input Watts value. Units are Watts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.20 |
| pdu3InputPhasePowerWattHour mandatory A kWatt-Hour value for each Input phase. Units are kWh. This value can be reset to 0
using GUI. In that case, the pdu3InputPhasePowerWattHourTimer will be reset as well
A ne… | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.21 |
| pdu3InputPhasePowerWattHourTimer mandatory Timestamp of when input phase kWatt-hours (kWh) was last reset. | column | OctetString | .1.3.6.1.4.1.232.165.11.2.2.1.22 |
| pdu3InputPhasePowerFactor mandatory An input PF value. Return value is divided by 100, for example a power factor
of 0.95 would be returned as 95. A negative value indicates that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.23 |
| pdu3InputPhasePowerVAR mandatory An input VA Reactive value. Units are in VAR. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.24 |
| pdu3InputPhaseVoltage mandatory An input voltage measurement value. Return value is divided by 10. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.3 |
| pdu3InputPhaseVoltageThStatus mandatory Status of the measured input voltage relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.232.165.11.2.2.1.4 |
| pdu3InputPhaseVoltageThLowerWarning mandatory Lower warning threshold. Return value is divided by 10. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.5 |
| pdu3InputPhaseVoltageThLowerCritical mandatory Lower critical threshold. Return value is divided by 10. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.6 |
| pdu3InputPhaseVoltageThUpperWarning mandatory Upper warning threshold. Return value is divided by 10. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.7 |
| pdu3InputPhaseVoltageThUpperCritical mandatory Upper critical threshold. Return value is divided by 10. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.2.2.1.8 |
| pdu3InputPhaseCurrentMeasType mandatory Which input wire is being measured in this table row - single phase, neutral, phase 1,
phase 2, or phase 3. | column | Enumeration | .1.3.6.1.4.1.232.165.11.2.2.1.9 |