pdu2InputPhaseEntry
CPQPOWER-MIB ·
.1.3.6.1.4.1.232.165.7.2.2.1
Object
row
mandatory
The input table entry containing the voltage, current, frequency, power for each phase. Entries are given with number of pdu and number of input phase 1, 2, or 3.
Context
- MIB
- CPQPOWER-MIB
- OID
.1.3.6.1.4.1.232.165.7.2.2.1- Type
- row
- Status
- mandatory
- Parent
- pdu2InputPhaseTable
- Table
- pdu2InputPhaseTable
- Children
- 25
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pdu2InputPhaseIndex mandatory Index for the Pdu2InputEntry table. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.1 |
| pdu2InputPhaseCurrentRating mandatory Rated current capacity of the input. A negative value indicates that
the hardware current capacity is unknown. Units are milliamps. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.10 |
| pdu2InputPhaseCurrent mandatory An input current measurement value. Units are milliamps. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.11 |
| pdu2InputPhaseCurrentThStatus mandatory Status of the measured input current relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.232.165.7.2.2.1.12 |
| pdu2InputPhaseCurrentThLowerWarning mandatory Lower warning threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.13 |
| pdu2InputPhaseCurrentThLowerCritical mandatory Lower critical threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.14 |
| pdu2InputPhaseCurrentThUpperWarning mandatory Upper warning threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.15 |
| pdu2InputPhaseCurrentThUpperCritical mandatory Upper critical threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.16 |
| pdu2InputPhaseCurrentCrestFactor mandatory Current crest factor. Units are in milli, for example a crest factor of
1.414 will be returned as 1414. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.17 |
| pdu2InputPhaseCurrentPercentLoad mandatory Current percent load, based on the rated current capacity. Units are
percentage, for example 80% will be returned as 80. A negative
value indicates that this object is not avail… | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.18 |
| pdu2InputPhasePowerMeasType mandatory Which input wire is being measured in this table row - single phase, neutral, phase 1,
phase 2, or phase 3. | column | Enumeration | .1.3.6.1.4.1.232.165.7.2.2.1.19 |
| pdu2InputPhaseVoltageMeasType mandatory Value indicates what input voltage is being measured in this table row - single phase
voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2,
phas… | column | Enumeration | .1.3.6.1.4.1.232.165.7.2.2.1.2 |
| pdu2InputPhasePowerVA mandatory An input VA value. Units are VA. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.20 |
| pdu2InputPhasePowerWatts mandatory An input Watts value. Units are Watts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.21 |
| pdu2InputPhasePowerWattHour mandatory A Watt-Hour value for each Input phase. Units are WH. This value can be reset to 0
using GUI. In that case, the pdu2InputPhasePowerWattHourTimer will be reset as well
A nega… | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.22 |
| pdu2InputPhasePowerWattHourTimer mandatory Timestamp of when input Watt-hours (inputWh) was last reset. | column | OctetString | .1.3.6.1.4.1.232.165.7.2.2.1.23 |
| pdu2InputPhasePowerFactor mandatory An input PF value. Units are in thousandths, for example a power factor
of 0.958 would be returned as 958, and 0.92 would be returned
as 920. A negative value indicates that t… | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.24 |
| pdu2InputPhasePowerVAR mandatory An input VAR value. Units are VAR. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.25 |
| pdu2InputPhaseVoltage mandatory An input voltage measurement value. Units are millivolts. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.3 |
| pdu2InputPhaseVoltageThStatus mandatory Status of the measured input voltage relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.232.165.7.2.2.1.4 |
| pdu2InputPhaseVoltageThLowerWarning mandatory Lower warning threshold. Units are millivolts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.5 |
| pdu2InputPhaseVoltageThLowerCritical mandatory Lower critical threshold. Units are millivolts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.6 |
| pdu2InputPhaseVoltageThUpperWarning mandatory Upper warning threshold. Units are millivolts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.7 |
| pdu2InputPhaseVoltageThUpperCritical mandatory Upper critical threshold. Units are millivolts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.8 |
| pdu2InputPhaseCurrentMeasType mandatory Which input wire is being measured in this table row - single phase, neutral, phase 1,
phase 2, or phase 3. | column | Enumeration | .1.3.6.1.4.1.232.165.7.2.2.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| pdu2IdentIndex mandatory Index for the Pdu2IdentEntry table. | column | Integer32 | .1.3.6.1.4.1.232.165.7.1.2.1.1 |
| pdu2InputPhaseIndex mandatory Index for the Pdu2InputEntry table. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.1 |