pdu2InputPhaseCurrentThLowerCritical
CPQPOWER-MIB ·
.1.3.6.1.4.1.232.165.7.2.2.1.14
Object
column
mandatory
Integer32
Lower critical threshold. Units are milliamps. A negative value indicates that this object is not available.
Context
- MIB
- CPQPOWER-MIB
- OID
.1.3.6.1.4.1.232.165.7.2.2.1.14- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- pdu2InputPhaseEntry
- Table
- pdu2InputPhaseTable
- Siblings
- 24
Syntax
Integer32
Values & Constraints
Object Constraints
range: -1-100000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pdu2InputPhaseIndex mandatory Index for the Pdu2InputEntry table. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.1 |
| pdu2InputPhaseCurrentRating mandatory Rated current capacity of the input. A negative value indicates that
the hardware current capacity is unknown. Units are milliamps. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.10 |
| pdu2InputPhaseCurrent mandatory An input current measurement value. Units are milliamps. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.11 |
| pdu2InputPhaseCurrentThStatus mandatory Status of the measured input current relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.232.165.7.2.2.1.12 |
| pdu2InputPhaseCurrentThLowerWarning mandatory Lower warning threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.13 |
| pdu2InputPhaseCurrentThUpperWarning mandatory Upper warning threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.15 |
| pdu2InputPhaseCurrentThUpperCritical mandatory Upper critical threshold. Units are milliamps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.16 |
| pdu2InputPhaseCurrentCrestFactor mandatory Current crest factor. Units are in milli, for example a crest factor of
1.414 will be returned as 1414. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.17 |
| pdu2InputPhaseCurrentPercentLoad mandatory Current percent load, based on the rated current capacity. Units are
percentage, for example 80% will be returned as 80. A negative
value indicates that this object is not avail… | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.18 |
| pdu2InputPhasePowerMeasType mandatory Which input wire is being measured in this table row - single phase, neutral, phase 1,
phase 2, or phase 3. | column | Enumeration | .1.3.6.1.4.1.232.165.7.2.2.1.19 |
| pdu2InputPhaseVoltageMeasType mandatory Value indicates what input voltage is being measured in this table row - single phase
voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2,
phas… | column | Enumeration | .1.3.6.1.4.1.232.165.7.2.2.1.2 |
| pdu2InputPhasePowerVA mandatory An input VA value. Units are VA. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.20 |
| pdu2InputPhasePowerWatts mandatory An input Watts value. Units are Watts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.21 |
| pdu2InputPhasePowerWattHour mandatory A Watt-Hour value for each Input phase. Units are WH. This value can be reset to 0
using GUI. In that case, the pdu2InputPhasePowerWattHourTimer will be reset as well
A nega… | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.22 |
| pdu2InputPhasePowerWattHourTimer mandatory Timestamp of when input Watt-hours (inputWh) was last reset. | column | OctetString | .1.3.6.1.4.1.232.165.7.2.2.1.23 |
| pdu2InputPhasePowerFactor mandatory An input PF value. Units are in thousandths, for example a power factor
of 0.958 would be returned as 958, and 0.92 would be returned
as 920. A negative value indicates that t… | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.24 |
| pdu2InputPhasePowerVAR mandatory An input VAR value. Units are VAR. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.25 |
| pdu2InputPhaseVoltage mandatory An input voltage measurement value. Units are millivolts. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.3 |
| pdu2InputPhaseVoltageThStatus mandatory Status of the measured input voltage relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.232.165.7.2.2.1.4 |
| pdu2InputPhaseVoltageThLowerWarning mandatory Lower warning threshold. Units are millivolts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.5 |
| pdu2InputPhaseVoltageThLowerCritical mandatory Lower critical threshold. Units are millivolts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.6 |
| pdu2InputPhaseVoltageThUpperWarning mandatory Upper warning threshold. Units are millivolts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.7 |
| pdu2InputPhaseVoltageThUpperCritical mandatory Upper critical threshold. Units are millivolts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.7.2.2.1.8 |
| pdu2InputPhaseCurrentMeasType mandatory Which input wire is being measured in this table row - single phase, neutral, phase 1,
phase 2, or phase 3. | column | Enumeration | .1.3.6.1.4.1.232.165.7.2.2.1.9 |